position, the machine indicates the unbalance value on a display, whereas the
other display shows the message "d1" or "d2" alternately to the distance value of
the plane corresponding to the body.
Move the sensor to the position shown on the display in which the message "d1"
or "d2" appears alternately to the distance value (the distance is read on the rule).
6
Turn the end of the measuring arm until the weight adhesive strip is in line with the
rim surface.
7
Press the key (Fig. 18d) to eject the weight and make it stick to the rim.
8
Return the measuring arm to the rest position (Fig.18e).
9
Repeat the operations to apply the second balancing weight.
10 Perform a test wheel spin to check the balancing accuracy.
The rim surface must be perfectly clean to make the weight stick efficiently to the rim. If
necessary, clean the surface using suitable cleansing products.
• Manually applied adhesive weights
1 Select the first side to be balanced
2 Turn the wheel until the central element of the corresponding position indicator lights
up.
3 Apply the adhesive weight manually in the position in which the relative plane was
measured, using the centre of gravity of the weight itself as reference. In this phase,
one display shows the unbalance value of the side to be balanced and the other shows
the message "H.12" that indicates the correct position of application as shown in figure
19.
WARNING
The machine allows the operator to select the method for applying the CLIP adhesive
weight at 6 o'clock (if the laser indicator is present) based on his requirements.
EM 9250 - EM 9250 C CompactLine Operator's manual
18
UK