Mondolfo Ferro Aquila Tornado Manual De Uso página 183

Idiomas disponibles
  • ES

Idiomas disponibles

Air circuit leak
- Repair the leak
Broken solenoid valve.
- Contact support service.
A11
Infl ation or defl ation time which is too long
A12
The pressure has not decreased after several attempts
Air circuit obstruction
- Remove obstruction.
Broken solenoid valve.
- Contact support service.
A13
Pressure which is too high
A14
eeprom read error
A15
eeprom write error
In addition to error messages, other messages may also appear on the display to indicate
machine status. These are:
AU
Self-calibration programme;
uuu
This message appears on the large screen during self-calibration and indicates that the
pressure value is being read: do not move the air hose or change the pressure.
6.2. CAMERA
From the main screen (Fig. 52), press the
button.
The camera is an electronic precision instrument
52
to display all operations carried out on the tyre
underside, on a specifi c screen, guaranteeing ma-
ximum control for the operator. The camera also has an automatic luminosity regulation
system for correct vision at any time of the day.
User manual Aquila Tornado
183