Disuse (over 30 days)
Annually
A3 TROUBLESHOOTING
Fault
Drop in pressure and/or flow
rate downstream of the filter
Leakage from the drain
valve.
Water
delivered
unpleasant smell/taste
Coarse material in filtered
water
Water leakage from the
system
A4 DISPOSAL
Dispose of separately from other waste. Hand in the end-of-life device at a suitable segregated waste collection
centre. Before disposing of the waste and in the event of any doubts, contact your local waste management
service for clarification.
A5 MARKING
The device has a label displaying the product technical data (see theTechnical diagrams and data sheet). It
includes the serial number (SN) with the production date (month/year) and production batch number, which are
required to activate the warranty.
ASSEMBLY AND INSTALLATION MANUAL
B1 INSTALLATION
B1.1 Prior to installation
The filters are delivered in packaging that provides adequate protection from external contamination. Transport
and store the equipment in its original, unopened packaging. During transport and storage, the equipment should
not be exposed to temperatures below 5°C or above 40°C. In the event of very heavy shocks during transport
or assembly, do not install the equipment but replace it, even if there is no obvious damage to the plastic parts.
To avoid external contamination, always keep the filter closed in its original box and remove it only immediately
prior to installation. After opening the box, check the integrity of the equipment and the presence of all the
supplied items. If in doubt, refrain from using it and contact the supplier. Use only original replacement parts.
Filter sanitation
Cartridge: replacement (if necessary)
Filter sanitation
O-Ring: check tightness, if leakage change it
Pressure gauge: check operation
Cause
Dirty filter element.
Shut-off valves not fully open
Excessive flow rate through the
filter
Low input pressure
Broken or worn valve O-ring seal.
Drain valve not fully closed due to
a foreign body lodged in the
housing.
Filter unaligned.
with
Contaminated supply water
Prolonged disuse (stagnation)
High
concentration
material in the incoming water
Damaged or improperly positioned
cartridge
Bowl not closed properly.
Badly positioned or damaged O-
ring.
Solution
Flush
clean/replace the filter cartridge.
Contact a TSC.
Open
completely.
Reduce the flow rate delivered
by the filter.
Increase the supply pressure
Contact a TSC.
Contact a TSC.
Contact a TSC.
Check the pre-filtered water
characteristics
Flush
allowing the filter to drain for at
least 30 seconds.
of
coarse
Check the pre-filtered water
characteristics.
Check the cartridge. Replace if
necessary.
Contact a TSC.
Tighten the bowl thoroughly.
Check the O-ring seal. Replace
if necessary.
Contact a TSC.
Authorised TSC
Authorised TSC
the
filter
and/or
the
shut-off
valves
several
times
while