A3 Troubleshooting - Acqua Brevetti FT370 Manual De Instrucciones Para El Uso Y Mantenimiento

Filtro auto-limpiante automatico
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

A2.2 Inactivity
After long inactivity periods it is advisable to carry out the filter cleaning operation repeatedly (2/3 times)
In case the hydraulic distribution system was subjected to a cleaning and sanitization it would be necessary
to include PuliMATIC in the intervention as well. The sanitization is part of the extraordinary maintenance
and it must be performed by authorised service centres (C.A.T.) only.
A2.3 Periodic checks
It is advisable to make a biannual check by an authorized technician to verify the proper operation of the
equipment.
A2.4 Extraordinary maintenance
Extraordinary maintenance or repair may affect the functional and/or safety features if improperly executed:
all these operations are deliberately omitted in this manual. Hence all extraordinary maintenance and repair
operations not covered in this manual should be performed by authorized Acqua Brevetti s.r.l personnel
only or by a local delegate specifically authorized.
Acqua Brevetti s.r.l. has created and organized an efficient local technical assistance extended to the whole
country with trained technicians who are available to assist you in order to ensure the proper operation of
the equipment. In case of damages or peculiar problems please contact Acqua Brevetti s.r.l.

A3 TROUBLESHOOTING

Problem
Green led off
Yellow led on
Yellow led flashing on and
off every secon
Yellow led flashing on and
off every 2 seconds
Water loss from the filter
drain
Refer to
www.acquabrevetti.it
MAN141 – Rev.1
PULIMATIC - ENGLISH
Cause
Reduced voltage.
Defective feeder.
Electrical circuit out of order.
Filter is cleaning
Circuit has crashed.
After every washing cycle the
filter remains in waiting position
2 minutes before taking any
cleaning intervention signal.
The black central button placed
in the middle of the
between two led could be
blocked.
The filter doesn't carry out the
cleaning
because
mechanically stressed
The black button placed in the
center of the
cover between
the leds may be blocked
Discharge
valve
may
tampered with or blocked
Discharge valve in out of phase
position.
web site for the closest C.A.T. List.
Solution
Check the power supply.
Replace the feeder.
Replace the electrical circuit.
Wait for the washing cycle to end.
Switched off the electrical power and restore it.
If the problem persists, get in touch with
C.A.T.
Wait for the waiting time to pass, then launch a
new cleaning cycle.
Verify that the cover doesn't force the black
carter
button placed between the two leds on manual
washing functioning and, in case, fix it..
Close the main water or put the equipment in
it
is
by pass position; contact a C.A.T.
Verify that the cover doesn't force the black
button placed between the two leds on manual
washing functioning and, in case, fix it.
be
contact a C.A.T.
contact a C.A.T.
PAG. E-10
Tabla de contenido
loading

Este manual también es adecuado para:

Ft360Ft372Ft362Ft374Ft364Ft376 ... Mostrar todo

Tabla de contenido