4
Technical data
4.1
Breaker
For details of the rated voltage, frequency, current and input power, please refer to the power tool's
country-specific type identification plate.
When powered by a generator or transformer, the generator or transformer's power output must be at least
twice the rated input power shown on the rating plate of the power tool. The operating voltage of the
transformer or generator must always be within +5% and -15% of the rated voltage of the power tool.
Weight in accordance with EPTA procedure 01
4.2
Noise information and vibration values in accordance with EN 62841
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure.
The data given represent the main applications of the power tool. However, if the power tool is used for
different applications, with different accessory tools, or is poorly maintained, the data can vary. This can
significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the power tool is switched
off, or when it is running but not actually being used for a job. This can significantly reduce exposure over
the total working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise information
Sound power level (L
WA
Sound pressure level (L
Uncertainty (noise values) (K
Total vibration
Chiseling (a
)
h,Cheq
Uncertainty (total vibration)
5
Operation
5.1
Preparations at the workplace
CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
5.1.1
Fitting the side handle
CAUTION
Risk of injury! Loss of control over the breaker.
▶ Check that the side handle is fitted correctly and tightened securely.
1. Slide the side handle clamping band over the chuck from the front and into the recess provided.
2. Bring the side handle into the desired position.
3. Secure the side handle by turning the knob until the clamping band is tight.
6
English
)
)
pA
and K
)
pA
WA
2
TE 500AVR
6.3 kg
104 dB(A)
93 dB(A)
3 dB(A)
8.2 m/s²
1.5 m/s²
2146361
*2146361*