ATTENTION!
You can also activate the automatic cleaning system for the coffee groups
through the keyboard, pressing key 5 and immediately and without releasing
this one press also key 1 of the button panel belonging to the group we want
to clean. If we need to stop the process before it ends, press key 5 of the same
button panel.
C
CALENDAR. It is possible to set time and day, and also to program the
automatic start and shutdown of the machine.
D
SETTINGS. Allowing to modify main working parameters, such
as temperature, cup volume setting, maintenance, and technical
parameters.
Set boiler and coffee groups temperature
Maintenance parameters, including general maintenance alarm, and
water filter alarm.
Technical parameters, including Exhibition mode, maximum filling
time for boiler, OFFSET temperature for coffee groups, CE parameter
configuration, activation of steam boiler, and level prove sensitivity.
PASSWORD: 66666
Factory settings, such as number of groups and PID configuration.
ATTENTION!
Exhibition mode allows machine to be switched ON with all heating elements
disabled, just for exhibition purpose.
Program automatic start and
shutdown
Set time and day
Set cup volume on each
selection for coffee groups
Set pre-infusion time on each
selection for coffee groups
21