5 Technical data

Right of technical changes reserved.
Tool
Weight
Dimensions (L x W x H)
en
Maximum fastener length
Cartridges
Power regulation
Contact movement
Contact pressure
Ambient operating temperature range
Recommended maximum fastening rate

6 Before use

NOTE
Read the operating instructions before the tool is oper-
ated for the first time.

7 Guidelines

7.1 Fastening guidelines
These guidelines must be observed at all times.
NOTE
For detailed information, please ask your local Hilti sales and service office for a copy of the applicable technical
guidelines or national technical regulations.
7.1.1 Minimum distances and spacing
Minimum distances and spacing when fastening to steel
22
Printed: 14.04.2014 | Doc-Nr: PUB / 5069866 / 000 / 03
All manuals and user guides at all-guides.com
DX E‑72
2.0 kg
384 mm × 48 mm × 153 mm
72 mm
5.6/16 (22 cal. short) brown, green, yellow, red
4 cartridge power levels
16 mm
100 N
-15...+50°C
250/h
6.1 Check the tool
WARNING
Do not operate the tool when parts are damaged
or when the controls do not function correctly. If
necessary, have the tool repaired at an authorized
Hilti service center.
Check that there is no cartridge in the tool. If there is a
cartridge in the tool, remove it from the tool by hand.
Check all external parts of the tool for damage and check
that all controls operate faultlessly.
Check the piston and stop ring for wear and ensure that
the parts have been fitted correctly.
A
B
C
min. edge distance = 15 mm (⁵⁄₈")
min. spacing = 20 mm (³⁄₄")
min. base material thickness = 4 mm (⁵⁄₃₂")