Produzido por Tecnomotor Eletrônica do Brasil S/A - REPRODUÇÃO PROIBIDA - Eventuais erros ou defeitos favor comunicar
[email protected]
Error
87
Code
Probable Cause
- "F1" ou "RET." key was pressed during an
ongoing process.
Error
88
Code
Probable Cause
- Some unknown error occurred during the
process, generating invalid data and
information, and was lost in the system.
Error
89
Code
Probable Cause
- An attempt to access a function or menu not
available in the system.
Error
90
Code
Probable Cause
- External temperature is too low, below 10°C.
- Problem in temperature control.
- Damaged resistance.
- Bad contact in the electrical connections of the
temperature sensor.
- Bad contact in the electrical connections of the
resistance circuit.
- Damaged temperature sensor.
- Damaged tank level sensor.
TM 514 – COMMON RAIL TEST
Functional Error!
Emergency stop. Check problems
- Restart the process.
- If it persists, call technical assistance.
Not identified. If this persists, notify the manufacturer.
- Restart the equipment and repeat the process.
- If it persists, call technical assistance.
Function unavailable.
Please, contact the factory.
- Restart the equipment and repeat the process.
- If it persists, Call Tecnomotor technical
assistance or sales desk.
Functional error!
Impossible to heat tank fluid.
- Restart the equipment and repeat the process.
- Check the ambient temperature.
- Call technical assistance.
233
Solution
Solution
Solution
Solution