TM 514 – COMMON RAIL TEST
Produzido por Tecnomotor Eletrônica do Brasil S/A - REPRODUÇÃO PROIBIDA - Eventuais erros ou defeitos favor comunicar
[email protected]
Mounting and closing the injection filter manually
1- Position the components as the image below. Pay attention to the
orientation of the sintered filter: the closed face of the filter must be in
contact with the spring.
Use a light force to overcome the spring force and find the initial thread. Be
careful with the spring force when closing. Protect your eyes to avoid accidents.
2- Rotate the filter body clockwise to close.
Check the o´rings on the set. If any are broken or deformed, replace them.
NOTE: Close the filter assembly by screwing with your hands. Do not use
wrenches or pliers to close the filter, as there is a risk of rupture of the
o´rings.
ATTENTION: The use of the filter with the sintered element different from
the one supplied by TECNOMOTOR, dirty or obstructed can cause rupture
of the hoses and deviations of measurement values, as well as damage to
the measuring system and loss of warranty of the equipment.
226