Produzido por Tecnomotor Eletrônica do Brasil S/A - REPRODUÇÃO PROIBIDA - Eventuais erros ou defeitos favor comunicar [email protected]
Error
5
Code
Probable Cause
- Bad contact in the electrical connection of
the system pressure sensor.
- Damaged system pressure sensor.
Error
6
Code
Probable Cause
- Accumulation of impurities in the hydraulic
system.
- Bad contact in meter(s) level sensor(s)
connection(s)
- Level sensor(s) locked.
- Clogged drain valve or tube.
- Damaged drain valve.
- Valve fuse blown.
- Damaged power board.
Error
7
Code
Probable Cause
- Problems with temperature control.
- Ventilation obstructed.
- Heat radiator with excess dirt.
- Fan will not turn on or damage propeller.
- Bad contact between temperature sensor
connections.
- Damaged temperature sensor.
- Injector with leak problems.
- Damaged power board.
Error
8
Code
Probable Cause
- Temperature less than <-15 °C.
- Problem in temperature control.
- Damaged resistance.
- Bad contact in temperature sensor
connections.
- Damaged temperature sensor.
Error
86
Code
Probable Cause
- Safety cover was open during a process.
- A bad or locked contact in the cover sensor.
- Damaged sensor.
TM 514 – COMMON RAIL TEST
Functional error!
Critical problem in the Rail pressure sensor.
- Check the correct grounding of the
equipment.
- Call technical assistance.
Functional error!
Impossible to empty meters.
- Check the valve fuse.
- Contact Technical Assistance to perform the
complete periodic maintenance.
Critical error!
Temperature is very high. Turn it off!
- Check that the fan is turning on during the test.
- Check that the ventilation inlets and outlets are
not obstructed.
- Check that the radiator is not dirty.
- Check that the injector has a operation leak
minimum.
- Call technical assistance.
Critical error!
Very low temperature, turn it off.
- Check the ambient temperature.
- Call technical assistance.
Safety error!
Safety cover open!
- Close safety cover and restart process.
- Call technical assistance.