TM 514 – COMMON RAIL TEST
Produzido por Tecnomotor Eletrônica do Brasil S/A - REPRODUÇÃO PROIBIDA - Eventuais erros ou defeitos favor comunicar
[email protected]
Checking and cleaning sintered filters
The filters must be checked and cleaned following the topics "Inspection of the
back leak filter" and "Inspection of the injection filter" every time the software
presents the verification warning "ALERT! Check the back leak and injection
filters". Never ignore this warning and follow the steps provided.
The warning frequency is set to occur every 20 hours of work. If it is necessary to
reduce this time, contact technical support so that this time is reduced. Never
ignore this hour meter.
Replacement of sintered filters after the hour meter expires
The filters must be replaced after 200 hours of work, but must also be replaced
if they show signs of efficiency loss, dirt in the pores and permanent clogging.
The frequency of the change notice is set to occur every 200 hours of work. If it is
necessary to reduce this time, contact technical support so that this time is
reduced. Never ignore this hour meter.
219