3.4
Essential requirements
The MD 30 may only be operated by
qualified and trained personnel.
The use of third-party products is the
responsibility of the operator.
Functionality and patient safety cannot be
guaranteed with third-party accessories.
Repairs may only be performed by
authorized NOUVAG service technicians.
3.5
During use
The device is not sterile on delivery. All
sterilizable parts must be sterilized before
use (see Chapter 8 Cleaning, disinfection
and sterilization).
Handpieces and contra angles may only
be attached when the electronic motor is
not running.
To prevent injury, never touch drill bits or
burrs while they are still running.
4
Scope of delivery
Art. No. Description
3330
MD 30 control unit -------------------------------------------------------------------------------------------------- 1 unit
1510
Vario pedal; IP68; electronic -------------------------------------------------------------------------------------- 1 unit
2097
Electronic motor 21 incl. 2 m motor cable --------------------------------------------------------------------- 1 unit
1706
Tube set, sterile, 2 m, single-use --------------------------------------------------------------------------------- 1 unit
1873
Clip set (10 pieces) for tube set attachment at motor cable----------------------------------------------- 1 unit
1881
Clip set (3 pieces) for tube set attachment at handpieces and contra angles ------------------------- 1 unit
1707
Irrigation fluid; 0.9% sodium chloride/water solution, 1 liter --------------------------------------------- 1 unit
1770
Stand for irrigation fluid ------------------------------------------------------------------------------------------- 1 unit
1170
Handpiece cradle ---------------------------------------------------------------------------------------------------- 1 unit
1974
Spray nozzle for Nou-Clean spray; for care of electronic motor------------------------------------------ 1 unit
1958
Spray nozzle for Nou-Clean spray; for care of instruments------------------------------------------------ 1 unit
31686
User Manual MD 30 on CD-ROM-------------------------------------------------------------------------------- 1 unit
In line with regulations pertaining to hazardous materials, the following items are not delivered with
the control unit and must be ordered separately:
1984
Nou-Clean maintenance and care spray ----------------------------------------------------------------------- 1 unit
4
All manuals and user guides at all-guides.com
Improper use or repair of the device and failure to
observe these instructions relieve us from any
obligation arising from warranty provisions or other
claims.
Prior to using the device, before startup, and before
operation, the user must always ensure that the
device and accessories are in good working order
and are clean, sterile and operational.
Use Nou-Clean spray for maintenance and care of
the motor, handpieces and contra angles. Using
other care products can result in malfunctions
and/or cause the warranty to be revoked.
At the choosing of the instrument the operator has
to make sure it's biocompatible, according to
EN ISO 10993.
Never operate the clamping mechanism of the
handpieces or contra angles while the system is
running. This could result in instrument damage.
MD 30 Operating Instructions, Art. No. 31686, V45/12
MD 30
Quantity