7.2.2) Level one programming (ON-OFF functions).
Level 1 functions are all factory set to "OFF". However, they can be changed at any time as shown in Table 8. Follow the procedure careful-
ly, as there is a maximum time of 10 seconds between pressing one key and another. If a longer period of time lapses, the procedure will fin-
ish automatically and memorize the modifications made up to that stage.
Table 8: changing ON-OFF functions
Press the key [Set] and hold it down (approx. 3 s)
1.
Release the [Set] key when L1 LED starts flashing
2.
Press keys [▲] or [▼] to move the flashing LED onto the LED representing
3.
the function which is to be changed
Press the [Set] key to change the state of the
4.
function (short flashing = OFF; long flashing = ON)
Wait 10 seconds before leaving the programme to allow the maximum time to lapse.
5.
Note: Points 3 and 4 can be repeated during the same programming phases in order to set other functions to ON or OFF
7.2.3 Level two functions (adjustable parameters)
Table 9: programmable function list: level two
Input LED
Parameter
L1
Pause
Time
L2
Step-by-step
L3
Motor
speed
L4
Open Gate Indi-
cator Output
L5
Motor
force
14
LED (level)
L1
5 seconds
L2
15 seconds
L3
30 seconds
L4
45 seconds
L5
60 seconds
L6
80 seconds
L7
120 seconds
L8
180 seconds
L1
Open – stop – close - stop
L2
Open – stop – close - open
L3
Open – close – open - close
L4
Condominium operation
L5
Condominium operation 2 (more than 2" causes stop)
L6
Step-by-Step 2 (less than 2" causes partial opening)Uomo presente
L7
Man present
L8
"Semiautomatic" opening,
"Man present " closing
L1
Very slow
L2
Slow
L3
Medium
L4
Fast
L5
Very fast
L6
Extremely Fast
L7
Opens "Fast"; closes "slow"
L8
Opens "Extremely Fast" Closes "Fast"
L1
Open Gate Indicator Function
L2
On if leaf closed
L3
On if leaf open
L4
Active with 2nd radio output
L5
Active with 3rd radio output
L6
Active with 4th radio output
L7
Maintenance indicator
L8
Electric lock
L1
Super light gate
L2
"Very light" gate
L3
"Light" gate
L4
"Average" gate
L5
"Average-heavy" gate
L6
"Heavy" gate
L7
"Very heavy" gate
L8
"Super heavy" gate
value
Adjusts the pause time, namely the time
which lapses before automatic closure.
This will only have an effect if automatic
closing is active.
Manages the sequence of controls associ-
ated to the Step-by-Step input or to the
1st radio command.
Adjusts the speed of the motor during nor-
mal travel.
Adjusts the function associated with the
S.C.A. output (whatever the associated
function may be, the output supplies a volt-
age of 24V –30 +50% with a maximum
power of 4W when active).
Adjusts the system which controls the
motor force in order to adapt it to the
weight of the gate. The force control sys-
tem also measures the ambient tempera-
ture, automatically increasing the force in
the event of particularly low temperatures.