Troubleshooting; Battery Charger; Product Identification; Unit Elements - CAMPAGNOLA TRONIC STAR Manual De Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

5 - USE OF THE TOOL
The battery charger (21) control is made for each of the 2 batteries with 2 lights. The one is green (22), the other one is red
(23). The batteries (2) charge follows the time sequence from 1 to 5:
GREEN LIGHT
RED LIGHT
1
OFF
OFF
2
ON
OFF
3
ON
Flashing
4
ON
ON
5
ON
OFF
When connecting a brand new or a flat battery (2), the battery charger (21) begins a pre-formatting phase at low current, with
the green light (22) on and the red light (23) flashing. Only after the battery (2) has reached the correct voltage level, the
charging phase begins, with the red light (23) on.
The battery re-charging time (26) depends on the cells capacity and the residual charge. The maximum charge time is 9 hours.

5.4 TROUBLESHOOTING

WARNING!
Maintenance shall be undertaken only by well-trained personnel.
FAULTS
The shear does not work.
The shear is not powerful enough.
Excessive battery (2) consumption.
Temporary shear stopping during the use.
Flashing ON-OFF light (15).
The green lights (22) of the battery charger
(21) do not switch on.
The red lights (23) of the battery charger
(21) do not switch on.
6

- BATTERY CHARGER

6.1 Product identification

Thanks to a new technology, the battery charger (21) mod. C1 (2x20) does not require either a pre-discharge of the battery nor its
check-up.
This system allows to re-charge the batteries (2) even if they are only partially flat.

6.2 Unit elements

Network connecting cable (20).
Battery cable (24).
115/230 V voltage selector (25).
Fuse (26) (T1A).
Green starting light (22).
Red charge/signal light (23).
20 - 56
STATUS
• un-plugged plug (20)
• burnt fuse (26)
• not connected battery (2)
• battery (2) in short circuit
• brand new or completely flat battery (2); pre-formatting phase of the battery
• charging phase
• ended re-charge, charge maintaining phase
CAUSE
Flat batteries (2).
Battery fuse (4) failure.
Flat batteries (2).
Worn mobile blade (16).
Excessively tightened blade pin (32).
The mobile blade (16) is worn.
Motor overheating due to large size
branches cutting.
Flat batteries (2).
Fuse (26) failure.
Fuse (26) failure.
REMEDY
Re-charge the batteries (2).
Replace the fuse (4).
Re-charge the batteries (2).
Sharpen the blade (16) or replace it if it is
too worn.
Loosen the nut (30) .
Sharpen the blade (16) or replace it if it is
too worn.
Switch off the shear with the ON-OFF
switch (8) (position 0) and wait few seconds
before re-switchng it on.
Re-charge the batteries (2).
Replace the fuse (26).
Replace the fuse (26).
Tabla de contenido
loading

Tabla de contenido