Activating the zoom function
If the thermal imaging camera does not display a menu, the zoom
function can be used as follows:
Press the "left arrow/zoom" key.
The magnifying glass is displayed in the bottom display bar and
the thermal imaging camera operates with a two times zoom.
Press the same key again to switch off the zoom function.
Accessing application modes
NOTICE
i
i
Briefly press the ON/OFF key to return to the standard appli-
cation mode from any application mode.
To access an application mode, press the down arrow key.
The current active function appears at the bottom of the screen.
The following application modes can be accessed with the right arrow/
laser pointer or left arrow/zoom key. The corresponding symbol ap-
pears on the display.
Fire
The displayed image is optimized for firefighting operations: tem-
perature differences within hot areas are especially highlighted.
Persons
The displayed image is optimized for search and rescue opera-
tions: temperature differences within cool to warm areas are espe-
cially highlighted. This way e. g. persons can be detected better.
Thermal Scan™
If the Thermal Scan function is activated, all objects that are hotter
than the defined threshold are displayed in a different color.
To change the threshold, press the up arrow and then the right
arrow/laser pointer or left arrow/zoom key.
To activate the threshold, press the arrow down key.
To exit the selection, press the arrow down key.
36
Transferring data to a PC
CAUTION
!
The thermal imaging camera must be connected to another
device via the USB interface in a non-explosion hazard area
only.
Otherwise, an explosion may occur.
1. Using the USB cable, connect the thermal imaging camera to a
PC.
CAUTION
!
The thermal imaging camera is detected by the PC and the
images can be displayed on the PC with standard windows
functions. Caution! The data cannot be recovered once it has
been deleted!
NOTICE
i
i
The USB cable used must not be longer than 3 m.
The installation of the supplied PC software is required for ad-
ditional functions (see chapter 4.2.8 on page 34).
2. Start the software on the PC.
3. Store or analyze the data on the PC.