In order to achieve the test report results, please load the performance parameters retained
by the manufacturer and the quali ed tecnichian. They will use these parameters once
veri ed that, during the installation, it is possibile to reproduce the laboratory conditions.
Plumbing system connection
The connection of the stove to the plumbing system must be made ONLY by
specialized personnel who are capable of carrying out installation properly,
in compliance with current standards in the country of installation. The
manufacturer will not be held responsible for damage to persons or things in
the event of failed operation if the aforementioned warning is not complied
with. anti-condensation valve must be installed in the return
mandatory to install an anti-condensate valve on the return of the system,
set at 60 ° C. The valve isn't a standard thermostove component and it isn't
delivered with the thermostove.
Closed vessel system
This product has been designed and built to
work with closed vessel systems. In general,
the closed vessel system has the following
expansion as the expansion vessel pre-loaded.
In addition to the expansion device, the closed
vessel system must be provided in accordance
with current Italian UNI 10412-2 (2009) by:
•
safety valve
•
thermostat control of the circulator
•
device alarm sounds
•
temperature Indicator
•
pressure indicator
•
audio alarm
•
automatic adjustment
•
safety thermostat with manual reset
•
circulation system
68
Diagram connection kit without hot water
thermostove
RETURN
FLOW
A2
The pressure relief valve (C) must always be
connected to a water drain pipe. The tube must
be capable of withstanding high temperature
and pressure.
A1 = heating main ow 3/4 " M
A2 = heating return ow 3/4 " M
C = safety valve 3/4 " M
ow. It is
MAIN
FLOW
A 1
C