Remove the corn rod that supports the springs
and remove it as shown in the image below. Do
this by removing a spring at a time making sure
it does not fall within the tube bundle.
Repeat the same operation with the other three
springs present. Now the upper section to the
heat exchanger is free from any encumbrance so
as to allow a perfect cleaning.
To complete the cleaning of the exchanger it is also
necessary to clean the inspection compartment,
located to the left of the combustion chamber,
under the springs. Remove the aesthetic
components that prevent access (for example
the side).
100
Then unscrew the screws of the inspection plate
and remove it. With an aspirator remove all the
residue that has been deposited. Replace the
gasket and replace the plate.
Once a year is also recommended to clean
the upper compartment of the exchanger. To
make a proper cleaning is recommended to
suck the ash, remove all horizontal joints with a
screwdriver, then again suck the ash.
Following
the
cleaning
compartment
of
section,
store
the
This cover must be closed, as well as with
normal screws, with webbing in ceramic ber
rope to ensure the watertight closure of the
thermostove.
This general cleaning should be carried out at
the end of the season in order to facilitate the
general removal of all residues of combustion,
without waiting too long, because with time
and humidity these residues can become
compacted. Check the seal of the ceramic ber
gaskets on the door of the thermostove.
Then clean the ue system especially near the
ttings to "T" and any horizontal sections.
For safety, the frequency to clean
the smoke exhaust system is to de-
terminate by the frequency of use
of the thermo-stove.
of
the
upper
the
exchange
upper
closure
cover.