GE G60 Manual De Instrucciones página 628

Tabla de contenido
B.4 MAPA DE MEMORIA
F122
ENUMERACIÓN: TIPO DE SEÑAL DE ENTRADA DE ELEMENTO
0 = Fasor, 1 = RMS
F123
B
ENUMERACIÓN: TI SECUNDARIO
0 = 1 A, 1 = 5 A
F124
ENUMERACIÓN: LISTA DE ELEMENTOS
Máscara
Elemento
de bits
0
Phase Instantaneous Overcurrent 1
1
Phase Instantaneous Overcurrent 2
2
Phase Instantaneous Overcurrent 3
3
Phase Instantaneous Overcurrent 4
4
Phase Instantaneous Overcurrent 5
5
Phase Instantaneous Overcurrent 6
6
Phase Instantaneous Overcurrent 7
7
Phase Instantaneous Overcurrent 8
8
Phase Instantaneous Overcurrent 9
9
Phase Instantaneous Overcurrent 10
10
Phase Instantaneous Overcurrent 11
11
Phase Instantaneous Overcurrent 12
16
Phase Time Overcurrent 1
17
Phase Time Overcurrent 2
18
Phase Time Overcurrent 3
19
Phase Time Overcurrent 4
20
Phase Time Overcurrent 5
21
Phase Time Overcurrent 6
24
Phase Directional Overcurrent 1
25
Phase Directional Overcurrent 2
32
Neutral Instantaneous Overcurrent 1
33
Neutral Instantaneous Overcurrent 2
34
Neutral Instantaneous Overcurrent 3
35
Neutral Instantaneous Overcurrent 4
36
Neutral Instantaneous Overcurrent 5
37
Neutral Instantaneous Overcurrent 6
38
Neutral Instantaneous Overcurrent 7
39
Neutral Instantaneous Overcurrent 8
40
Neutral Instantaneous Overcurrent 9
41
Neutral Instantaneous Overcurrent 10
42
Neutral Instantaneous Overcurrent 11
43
Neutral Instantaneous Overcurrent 12
48
Neutral Time Overcurrent 1
49
Neutral Time Overcurrent 2
50
Neutral Time Overcurrent 3
51
Neutral Time Overcurrent 4
52
Neutral Time Overcurrent 5
53
Neutral Time Overcurrent 6
56
Neutral Directional Overcurrent 1
B-72
Máscara
de bits
57
60
61
64
65
66
67
68
69
70
71
72
73
74
75
80
81
82
83
84
85
86
87
88
89
90
91
101
125
140
144
145
148
152
154
156
160
161
162
190
210
211
214
215
221
222
224
225
226
227
228
229
Sistema de protección de generador G60
Elemento
Neutral Directional Overcurrent 2
Negative Sequence Directional Overcurrent 1
Negative Sequence Directional Overcurrent 2
Ground Instantaneous Overcurrent 1
Ground Instantaneous Overcurrent 2
Ground Instantaneous Overcurrent 3
Ground Instantaneous Overcurrent 4
Ground Instantaneous Overcurrent 5
Ground Instantaneous Overcurrent 6
Ground Instantaneous Overcurrent 7
Ground Instantaneous Overcurrent 8
Ground Instantaneous Overcurrent 9
Ground Instantaneous Overcurrent 10
Ground Instantaneous Overcurrent 11
Ground Instantaneous Overcurrent 12
Ground Time Overcurrent 1
Ground Time Overcurrent 2
Ground Time Overcurrent 3
Ground Time Overcurrent 4
Ground Time Overcurrent 5
Ground Time Overcurrent 6
Restricted Ground Fault 1
Restricted Ground Fault 2
Restricted Ground Fault 3
Restricted Ground Fault 4
Restricted Ground Fault 5
Restricted Ground Fault 6
Opposite Phase Rotation
Desequilibrio del generador
Subtensión auxiliar 1
Phase Undervoltage 1
Phase Undervoltage 2
Sobretensión auxiliar 1
Phase Overvoltage 1
Sobretensión compensada 1
Neutral Overvoltage 1
Phase Distance Zone 1
Phase Distance Zone 2
Phase Distance Zone 3
Detección de oscilación de potencia
Volt per Hertz 1
Volt per Hertz 2
Sensitive Directional Power 1
Sensitive Directional Power 2
Tierra del estátor 100 %
Split Phase Protection
SRC1 VT Fuse Failure
SRC2 VT Fuse Failure
SRC3 VT Fuse Failure
SRC4 VT Fuse Failure
SRC5 VT Fuse Failure
SRC6 VT Fuse Failure
APÉNDICE B