APÉNDICE B
Tabla B–9: MAPA DE MEMORIA DE MODBUS (Hoja 40 de 60)
DIR
NOMBRE DE REGISTRO
A211
Selector switch 2 position
Selector switch settings (lectura/escritura, 2 módulos)
A280
Selector 1 Function
A281
Selector 1 Range
A282
Selector 1 Timeout
A283
Selector 1 Step Up
A284
Selector 1 Step Mode
A285
Selector 1 Acknowledge
A286
Selector 1 Bit0
A287
Selector 1 Bit1
A288
Selector 1 Bit2
A289
Selector 1 Bit Mode
A28A
Selector 1 Bit Acknowledge
A28B
Selector 1 Power Up Mode
A28C
Selector 1 Target
A28D
Selector 1 Events
A28E
Reservado (10 elementos)
A298
...Repetido para Selector 2
DNP/IEC Points (configuración de lectura/escritura)
A300
DNP/IEC 60870-5-104 Binary Input Points
(256 elementos)
A400
DNP/IEC 60870-5-104 Analog Input Points
(256 elementos)
Volts Per Hertz (configuración agrupada de lectura/escritura) (2 módulos)
A580
Volts Per Hertz 1 Function
A581
Volts Per Hertz 1 Source
A582
Volts Per Hertz 1 Pickup
A583
Volts Per Hertz 1 Curves
A584
Volts Per Hertz 1 TD Multiplier
A585
Volts Per Hertz 1 Block
A586
Volts Per Hertz 1 Events
A587
Volts Per Hertz 1 Target
A588
Volts Per Hertz 1 T Reset
A589
Volts Per Hertz 1 Voltage Mode
A58A
...Repetido para Volts Per Hertz 2
Volts Per Hertz Actuals (solo lectura) (2 módulos)
A5A0
Volts Per Hertz 1
A5A1
Volts Per Hertz 2
Flexcurves C y D (configuración de lectura/escritura)
A600
FlexCurve C (120 elementos)
A680
FlexCurve D (120 elementos)
Non Volatile Latches (configuración de lectura/escritura) (16 módulos)
A700
Non-Volatile Latch 1 Function
A701
Non-Volatile Latch 1 Type
A702
Non-Volatile Latch 1 Set
A703
Non-Volatile Latch 1 Reset
A704
Non-Volatile Latch 1 Target
A705
Non-Volatile Latch 1 Events
A706
Reservado (4 elementos)
A70A
...Repetido para Non-Volatile Latch 2
A714
...Repetido para Non-Volatile Latch 3
A71E
...Repetido para Non-Volatile Latch 4
A728
...Repetido para Non-Volatile Latch 5
GE Multilin
RANGO
1 a 7
0 a 1
1 a 7
3 to 60
0 a 65535
0 a 1
0 a 65535
0 a 65535
0 a 65535
0 a 65535
0 a 1
0 a 65535
0 a 2
0 a 2
0 a 1
---
0 a 65535
0 a 65535
0 a 1
0 a 5
0.8 to 4
0 a 7
0.05 to 600
0 a 65535
0 a 1
0 a 2
0 a 1000
0 a 1
0 a 65.535
0 a 65.535
0 a 65535
0 a 65535
0 a 1
0 a 1
0 a 65535
0 a 65535
0 a 2
0 a 1
---
Sistema de protección de generador G60
B.4 MAPA DE MEMORIA
UNIDADES
PASO
FORMATO
---
1
F001
---
1
F102
---
1
F001
s
0.1
F001
---
1
F300
---
1
F083
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F083
---
1
F300
---
1
F084
---
1
F109
---
1
F102
---
1
F001
---
1
F300
---
1
F300
---
1
F102
---
1
F167
pu
0.01
F001
---
1
F240
---
0.01
F001
---
1
F300
---
1
F102
---
1
F109
s
0.1
F001
---
1
F186
pu
0.001
F001
pu
0.001
F001
ms
1
F011
ms
1
F011
---
1
F102
---
1
F519
---
1
F300
---
1
F300
---
1
F109
---
1
F102
---
---
F001
PREDETERMINADO
1
0 (Desactivado)
7
50
B
0
0 (Time-out)
0
0
0
0
0 (Time-out)
0
0 (Restore)
0 (restablecimiento
automático)
0 (Desactivado)
0
0
0
0 (Desactivado)
0 (SRC 1)
80
0 (tiempo definido)
100
0
0 (Desactivado)
0 (restablecimiento
automático)
10
0 (Phase-to-Ground)
0
0
0
0
0 (Desactivado)
0 (Reset Dominant)
0
0
0 (restablecimiento
automático)
0 (Desactivado)
0
B-49