B.4 MAPA DE MEMORIA
Tabla B–9: MAPA DE MEMORIA DE MODBUS (Hoja 31 de 60)
DIR
NOMBRE DE REGISTRO
DB3F
Aggregator 1 Include PMU3
DB40
Aggregator 1 Include PMU4
DB41
PMU Aggregator 1 Reserved (8 elementos)
DB49
...Repetido para el módulo número 2
Phasor Measurement Unit Calibration (configuración de lectura/escritura)
B
7949
PMU Va Calibration Angle
794A
PMU Va Calibration Magnitude
794B
PMU Vb Calibration Angle
794C
PMU Vb Calibration Magnitude
794D
PMU Vc Calibration Angle
794E
PMU Vc Calibration Magnitude
794F
PMU Vx Calibration Angle
7950
PMU Vx Calibration Magnitude
7951
PMU Ia Calibration Angle
7952
PMU Ia Calibration Magnitude
7953
PMU Ib Calibration Angle
7954
PMU Ib Calibration Magnitude
7955
PMU Ic Calibration Angle
7956
PMU Ic Calibration Magnitude
7957
PMU Ig Calibration Angle
7958
PMU Ig Calibration Magnitude
7959
PMU Sequence Voltage Shift Angle
795A
PMU Sequence Current Shift Angle
Phasor Measurement Unit Triggering (configuración de lectura/escritura)
79A1
PMU 1 User Trigger
Phasor Measurement Unit Current Trigger (configuración de lectura/escritura)
79A5
PMU 1 Current Trigger Function
79A6
PMU 1 Current Trigger Pickup
79A7
PMU 1 Current Trigger Pickup Time
79A8
PMU 1 Current Trigger Dropout Time
79A9
PMU 1 Current Trigger Block (3 elementos)
79AC
PMU 1 Current Trigger Target
79AD
PMU 1 Current Trigger Events
Phasor Measurement Unit df/dt Trigger (configuración de lectura/escritura)
79C9
PMU 1 df/dt Trigger Function
79CA
PMU 1 df/dt Trigger Raise
79CB
PMU 1 df/dt Trigger Fall
79CC
PMU 1 df/dt Trigger Pickup Time
79CD
PMU 1 df/dt Trigger Dropout Time
79CE
PMU 1 df/dt Trigger Block (3 elementos)
79D1
PMU 1 df/dt Trigger Target
79D2
PMU 1 df/dt Trigger Events
79D3
...Repetido para PMU 2
79DD
...Repetido para PMU 3
79E7
...Repetido para PMU 4
Field Current Protection Settings (configuración de lectura/escritura)
7A60
Field Current Function
7A61
Field Current Origin
7A62
Field Current OC Pickup
7A63
Field Current OC Delay
7A64
Field Current UC Pickup
7A65
Field Current UC Delay
7A66
Reservado
B-40
RANGO
0 a 1
0 a 1
0 a 1
-5 a 5
95 a 105
-5 a 5
95 a 105
-5 a 5
95 a 105
-5 a 5
95 a 105
-5 a 5
95 a 105
-5 a 5
95 a 105
-5 a 5
95 a 105
-5 a 5
95 a 105
-180 a 180
-180 a 180
0 a 65535
0 a 1
0.1 to 30
0 a 600
0 a 600
0 a 65535
0 a 2
0 a 1
0 a 1
0.1 a 15
0.1 a 15
0 a 600
0 a 600
0 a 65535
0 a 2
0 a 1
0 a 1
0 a 48
0.05 a 1
0 a 600
0.05 a 1
0 a 600
---
Sistema de protección de generador G60
UNIDADES
PASO
FORMATO
---
1
F126
---
1
F126
---
1
F001
°
0.05
F002
%
0.1
F002
°
0.05
F002
%
0.1
F002
°
0.05
F002
%
0.1
F002
°
0.05
F002
%
0.1
F002
°
0.05
F002
%
0.1
F002
°
0.05
F002
%
0.1
F002
°
0.05
F002
%
0.1
F002
°
0.05
F002
%
0.1
F002
°
30
F002
°
30
F002
---
1
F300
---
1
F102
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
Hz/s
0.01
F001
Hz/s
0.01
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
1
F151
pu
0.01
F001
s
0.01
F001
pu
0.01
F001
s
0.01
F001
---
---
F001
APÉNDICE B
PREDETERMINADO
0 (no)
0 (no)
0
0
1000
0
1000
0
1000
0
1000
0
1000
0
1000
0
1000
0
1000
0
0
0
0 (Desactivado)
1800
10
100
0
0 (restablecimiento
automático)
0 (Desactivado)
0 (Desactivado)
25
25
10
100
0
0 (restablecimiento
automático)
0 (Desactivado)
0 (Desactivado)
0 (ninguno)
80
100
20
100
0
GE Multilin