APÉNDICE B
Tabla B–9: MAPA DE MEMORIA DE MODBUS (Hoja 16 de 60)
DIR
NOMBRE DE REGISTRO
4701
Nombre de disyuntor 1
4704
Modo de disyuntor 1
4705
Apertura de disyuntor 1
4706
Cierre de disyuntor 1
4707
Breaker 1 phase A / three-pole closed
4708
Breaker 1 phase B closed
4709
Breaker 1 phase C closed
470A
Breaker 1 external alarm
470B
Breaker 1 alarm delay
470D
Breaker 1 pushbutton control
470E
Breaker 1 manual close recall time
4710
Breaker 1 out of service
4711
Breaker 1 block open
4712
Breaker 1 block close
4713
Breaker 1 phase A / three-pole opened
4714
Breaker 1 phase B opened
4715
Breaker 1 phase C opened
4716
Breaker 1 operate time
4717
Eventos de disyuntor 1
4718
Reservado
4719
...Repetido para Breaker 2
4732
...Repetido para Breaker 3
474B
...Repetido para Breaker 4
Synchrocheck (configuración de lectura/escritura) (2 módulos)
47A0
Función de control de sincronismo 1
47A1
Synchrocheck 1 V1 Source
47A2
Synchrocheck 1 V2 Source
47A3
Synchrocheck 1 Maximum Voltage Difference
47A5
Synchrocheck 1 Maximum Angle Difference
47A6
Synchrocheck 1 Maximum Frequency Difference
47A7
Synchrocheck 1 Dead Source Select
47A8
Synchrocheck 1 Dead V1 Maximum Voltage
47A9
Synchrocheck 1 Dead V2 Maximum Voltage
47AA
Synchrocheck 1 Live V1 Minimum Voltage
47AB
Synchrocheck 1 Live V2 Minimum Voltage
47AC
Destino de control de sincronismo 1
47AD
Eventos de control de sincronismo 1
47AE
Bloque de control de sincronismo 1
47AF
Synchrocheck 1 Frequency Hysteresis
47B0
...Repetido para control de sincronismo 2
Flexcurves A y B (configuración de lectura/escritura)
4800
FlexCurve A (120 elementos)
48F0
FlexCurve B (120 elementos)
Modbus User Map (configuración de lectura/escritura)
4A00
Modbus Address Settings for User Map (256 elementos)
User Displays Settings (configuración de lectura/escritura) (16 módulos)
4C00
User-Definable Display 1 Top Line Text
4C0A
User-Definable Display 1 Bottom Line Text
4C14
Modbus Addresses of Display 1 Items (5 elementos)
4C19
Reservado (7 elementos)
4C20
...Repetido para User-Definable Display 2
4C40
...Repetido para User-Definable Display 3
4C60
...Repetido para User-Definable Display 4
GE Multilin
RANGO
---
0 a 1
0 a 65535
0 a 65535
0 a 65535
0 a 65535
0 a 65535
0 a 65535
0 a 65535
0 a 1
0 a 65535
0 a 65535
0 a 65535
0 a 65535
0 a 65535
0 a 65535
0 a 65535
0 a 65535
0 a 1
---
0 a 1
0 a 5
0 a 5
0 a 400.000
0 a 100
0 a 2
0 a 5
0 a 1.25
0 a 1.25
0 a 1.25
0 a 1.25
0 a 2
0 a 1
0 a 65535
0 a 0.1
0 a 65535
0 a 65535
0 a 65535
---
---
0 a 65535
---
Sistema de protección de generador G60
B.4 MAPA DE MEMORIA
UNIDADES
PASO
FORMATO
---
---
F206
---
1
F157
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F003
---
1
F102
s
0.001
F003
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
---
1
F102
---
---
---
---
1
F102
---
1
F167
---
1
F167
V
1
F060
grados
1
F001
Hz
0.01
F001
---
1
F176
pu
0.01
F001
pu
0.01
F001
pu
0.01
F001
pu
0.01
F001
---
1
F109
---
1
F102
---
1
F300
Hz
0.01
F001
ms
1
F011
ms
1
F011
---
1
F001
---
---
F202
---
---
F202
---
1
F001
---
---
F001
PREDETERMINADO
"Bkr 1"
0 (3 polos)
0
0
0
B
0
0
0
0
0 (Desactivado)
0
0
0
0
0
0
0
70
0 (Desactivado)
---
0 (Desactivado)
0 (SRC 1)
1 (SRC 2)
10000
30
100
1 (LV1 and DV2)
30
30
70
70
0 (restablecimiento
automático)
0 (Desactivado)
0
6
0
0
0
" "
""
0
0
B-25