GE G60 Manual De Instrucciones página 573

Tabla de contenido
APÉNDICE B
Tabla B–9: MAPA DE MEMORIA DE MODBUS (Hoja 8 de 60)
DIR
NOMBRE DE REGISTRO
26BD
Operando IEC 61850 GGIO5 uinteger input 14
26BE
Operando IEC 61850 GGIO5 uinteger input 15
26BF
Operando IEC 61850 GGIO5 uinteger input 16
Enteros recibidos de IEC 61850 (solo lectura, valores reales)
26F0
IEC 61850 received uinteger 1
26F2
IEC 61850 received uinteger 2
26F4
IEC 61850 received uinteger 3
26F6
IEC 61850 received uinteger 4
26F8
IEC 61850 received uinteger 5
26FA
IEC 61850 received uinteger 6
26FC
IEC 61850 received uinteger 7
26FE
IEC 61850 received uinteger 8
2700
IEC 61850 received uinteger 9
2702
IEC 61850 received uinteger 10
2704
IEC 61850 received uinteger 11
2706
IEC 61850 received uinteger 12
2708
IEC 61850 received uinteger 13
270A
IEC 61850 received uinteger 14
270C
IEC 61850 received uinteger 15
270E
IEC 61850 received uinteger 16
THD y armónico de corriente de fuente (solo lectura) (6 módulos)
2800
Ia THD for Source 1
2801
Ia Harmonics for Source 1 - 2º a 25º (24 elementos)
2821
Ib THD for Source 1
2822
Ib Harmonics for Source 1 - 2º a 25º (24 elementos)
283A
Reservado (8 elementos)
2842
Ic THD for Source 1
2843
Ic Harmonics for Source 1 - 2nd to 25th (24 items)
285B
Reservado (8 elementos)
2863
...Repetido para fuente 2
28C6
...Repetido para fuente 3
2929
...Repetido para fuente 4
FlexStates expandidos (solo lectura)
2B00
FlexStates, uno por registro (256 elementos)
Estados expandidos de entrada/salida digital (solo lectura)
2D00
Estados de contacto de entrada, uno por registro
(96 elementos)
2D80
Estados de contacto de salida, uno por registro
(64 elementos)
2E00
Virtual Output States, uno por registro (96 elementos)
Estados expandidos de entrada/salida remota expandidos (solo lectura)
2F00
Remote Device States, one per register (16 elementos)
2F80
Remote Input States, uno por registro (64 elementos)
Valores de oscilografía (solo lectura)
3000
Número De disparos de oscilografía
3001
Oscillography Available Records
3002
Oscillography Last Cleared Date
3004
Oscillography Number Of Cycles Per Record
Comandos de oscilografía (comando de lectura/escritura)
3005
Oscillography Force Trigger
3011
Oscillography Clear Data
3012
Número De disparos de oscilografía
Comandos del informe de fallos programable por el usuario (comando de lectura/escritura)
3060
User Fault Report Clear
GE Multilin
RANGO
---
---
---
0 a 4294967295
0 a 4294967295
0 a 4294967295
0 a 4294967295
0 a 4294967295
0 a 4294967295
0 a 4294967295
0 a 4294967295
0 a 4294967295
0 a 4294967295
0 a 4294967295
0 a 4294967295
0 a 4294967295
0 a 4294967295
0 a 4294967295
0 a 4294967295
0 a 99.9
0 a 99.9
0 a 99.9
0 a 99.9
0 a 0.1
0 a 99.9
0 a 99.9
0 a 0.1
0 a 1
0 a 1
0 a 1
0 a 1
0 a 1
0 a 1
0 a 65535
0 a 65535
0 a 400.000.000
0 a 65535
0 a 1
0 a 1
0 a 32.767
0 a 1
Sistema de protección de generador G60
B.4 MAPA DE MEMORIA
UNIDADES
PASO
FORMATO
---
---
F612
---
---
F612
---
---
F612
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
0.1
F001
---
0.1
F001
---
0.1
F001
---
0.1
F001
---
0.1
F001
---
0.1
F001
---
0.1
F001
---
0.1
F001
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F155
---
1
F108
---
1
F001
---
1
F001
---
1
F050
---
1
F001
---
1
F126
---
1
F126
---
1
F001
---
1
F126
PREDETERMINADO
0
0
0
0
B
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 (apagado)
0 (apagado)
0 (apagado)
0 (apagado)
0 (Fuera De Línea)
0 (apagado)
0
0
0
0
0 (no)
0 (no)
0
0 (no)
B-17

Hide quick links:

Tabla de contenido
loading

Tabla de contenido