B.4 MAPA DE MEMORIA
Tabla B–9: MAPA DE MEMORIA DE MODBUS (Hoja 7 de 60)
DIR
NOMBRE DE REGISTRO
2548
PMU 1 Phase C Voltage Angle
2549
PMU 1 Auxiliary Voltage Magnitude
254B
PMU 1 Auxiliary Voltage Angle
254C
PMU 1 Positive Sequence Voltage Magnitude
254E
PMU 1 Positive Sequence Voltage Angle
B
254F
PMU 1 Negative Sequence Voltage Magnitude
2551
PMU 1 Negative Sequence Voltage Angle
2552
PMU 1 Zero Sequence Voltage Magnitude
2554
PMU 1 Zero Sequence Voltage Angle
2555
PMU 1 Phase A Current Magnitude
2557
PMU 1 Phase A Current Angle
2558
PMU 1 Phase B Current Magnitude
255A
PMU 1 Phase B Current Angle
255B
PMU 1 Phase C Current Magnitude
255D
PMU 1 Phase C Current Angle
255E
PMU 1 Ground Current Magnitude
2560
PMU 1 Ground Current Angle
2561
PMU 1 Positive Sequence Current Magnitude
2563
PMU 1 Positive Sequence Current Angle
2564
PMU 1 Negative Sequence Current Magnitude
2566
PMU 1 Negative Sequence Current Angle
2567
PMU 1 Zero Sequence Current Magnitude
2569
PMU 1 Zero Sequence Current Angle
256A
PMU 1 Frequency
256C
PMU 1 df/dt
256D
PMU 1 Configuration Change Counter
256E
Reservado (4 elementos)
Valores enteros de unidad de medida de fasor (solo lectura, registros de valores reales)
2608
PMU 1 SOC timestamp
260A
PMU 1 FRAMESEC timestamp
260C
Indicadores de la PMU 1 STAT
Entradas remotas de estado de doble punto (lectura/escritura, registros de configuración)
2620
Dispositivo de entrada remota de estado de doble punto 1
2621
Elemento de entrada remota de estado de doble punto 1
2622
Nombre de entrada remota de estado de doble punto 1
2628
Eventos de entrada remota de estado de doble punto 1
2629
... Repetido para entrada de estado de punto doble 2
2632
... Repetido para entrada de estado de punto doble 3
263B
... Repetido para entrada de estado de punto doble 4
2644
... Repetido para entrada de estado de punto doble 5
Configuración de IEC 61850 GGIO5 (registros de configuración de lectura/escritura)
26B0
Operando IEC 61850 GGIO5 uinteger input 1
26B1
Operando IEC 61850 GGIO5 uinteger input 2
26B2
Operando IEC 61850 GGIO5 uinteger input 3
26B3
Operando IEC 61850 GGIO5 uinteger input 4
26B4
Operando IEC 61850 GGIO5 uinteger input 5
26B5
Operando IEC 61850 GGIO5 uinteger input 6
26B6
Operando IEC 61850 GGIO5 uinteger input 7
26B7
Operando IEC 61850 GGIO5 uinteger input 8
26B8
Operando IEC 61850 GGIO5 uinteger input 9
26B9
Operando IEC 61850 GGIO5 uinteger input 10
26BA
Operando IEC 61850 GGIO5 uinteger input 11
26BB
Operando IEC 61850 GGIO5 uinteger input 12
26BC
Operando IEC 61850 GGIO5 uinteger input 13
B-16
RANGO
-359.9 a 0
0 a 999999.999
-359.9 a 0
0 a 999999.999
-359.9 a 0
0 a 999999.999
-359.9 a 0
0 a 999999.999
-359.9 a 0
0 a 999999.999
-359.9 a 0
0 a 999999.999
-359.9 a 0
0 a 999999.999
-359.9 a 0
0 a 999999.999
-359.9 a 0
0 a 999999.999
-359.9 a 0
0 a 999999.999
-359.9 a 0
0 a 999999.999
-359.9 a 0
2 a 90
-327,67 a 327,67
0 a 655.35
0 a 1
0 a 4294967295
0 a 4294967295
0 a 4294967295
1 a 32
0 a 128
1 a 64
0 a 1
---
---
---
---
---
---
---
---
---
---
---
---
---
Sistema de protección de generador G60
UNIDADES
PASO
FORMATO
°
0.1
F002
V
0.001
F060
°
0.1
F002
V
0.001
F060
°
0.1
F002
V
0.001
F060
°
0.1
F002
V
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
A
0.001
F060
°
0.1
F002
Hz
0.001
F003
Hz/s
0.01
F002
0.01
F001
---
1
F001
segundos
1
F003
segundos
1
F003
---
1
F003
---
1
F001
---
1
F156
---
1
F205
---
1
F102
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
APÉNDICE B
PREDETERMINADO
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0 (ninguno)
"Rem Ip 1"
0 (Desactivado)
0
0
0
0
0
0
0
0
0
0
0
0
0
GE Multilin