Transport And Storage - salmson SHC 2 kW Instrucciones De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ENGLISH
1. GENERAL
1.1. Applications
• Circulating pumps aimed for close circuit for cooling and heating
( low T° ).
• Pumps for clear liquids in residential, agricultural, industrial, and
other applications. Drawing of water from a well, spring, river, pond,
etc. Water should not be drawn from abyssinian wells (tube, driven
well).
• Can be use in swimming pool application ( circulation and reverse
flow swimming ) and aquarium on request.
1.2. Specifications
• Max. service pressure:
• Max. suction pressure:
• Temperature range:
• Ambient temperature:
• Suction head:
• Additive:
2. SAFETY
Read this data sheet carefully before installing and starting up. Pay
special attention to the points concerning the safety of the
equipment for the intermediate or end user.
2.1. Symbols used in the manual
Security instruction : no respect can induce injury.
Electric security instruction : no respect can induce injury.
Security instruction : no respect can be induced
ATTENTION !
material damages.

3. TRANSPORT AND STORAGE

When taking delivery of the equipment, check that it has not been
damaged in transit. If anything is found wrong, take the necessary
steps with the carrier within the allowed time.
If the equipment delivered is to be installed at a
ATTENTION !
later time, store it in a dry place and protect it
from impacts and outside hazards (moisture, frost, etc.).
Handle the pump carefully so as not to alter the geometry or
alignment of the hydraulic assembly.
4. PRODUCTS AND ACCESSORIES
4.1. Description (see Figs. 1 & 2)
1
: Foot valve-strainer (max. passage cross-section of 1 mm)
2
: Pump suction valve
3
: Pump discharge valve
4
: Check valve
5
: Filling plug
6
: Drain plug
7
: Pipe support
8
: Strainer
9
: Storage tank
10
: Town water supply
11
: Motor protection relay for three-phase motor
HA
: Suction head
HC
: Discharge head
4.2. The pump
Singlestage horizontal pump.
Not self-priming.
"Victaulic" typ or threaded ports, axial suction, radial discharge
direction.
Shaft sealing by standardized mechanical packing.
6,5 bar
4 bar
-20° to +65°C
-15° to +50°C (for higher
temperatures, get in touch
with us)
- Depends on NPSH of pump
- Ethylene glycol 35% max.
4.3. The motor
Protection index
: IP 54
Insulation class
: F
Single-phase motor: capacitor in terminal box, built-in thermal
protection with automatic reset.
FRÉQUENCY
SPEED
IN RPM
VOLTAGE*
3-PHASE
* Standard voltage; (50Hz) tolerance ± 10 % - (60Hz) tolerance ± 6 %
4.4. Accessories (optional)
• Suction kits • Isolating valves • Check valves • Foot valve-strainer
• Bladder or galvanized tanks • Anti-vibration sleeves • Motor
protection circuit-breaker • Dry-running protection • device for
On/Off control and dry-running protection • "Victaulic" coupling typ.
5. INSTALLATION
Two standard cases:
• Fig. 1: Pump in suction
• Fig. 2: Pump under pressure from storage tank (item 9) or town
water supply (item 10), with dry-running protection system.
5.1. Installation
Install the pump in a place that is easy to reach, protected from
frost, and as close as possible to the place from which water is
drawn.
Install the pump on a foundation block or directly on a smooth, level
floor.
Pump attached by two holes for 8-mm-dia. studs.
Bear in mind that the altitude of the place of
ATTENTION !
installation and the water temperature may
reduce the suction head of the pump.
Altitude
Loss of head
0 m
0 mCL
500 m
0,60 mCL
1000 m
1,15 mCL
1500 m
1,70 mCL
2000 m
2,20 mCL
2500 m
2,65 mCL
3000 m
3,20 mCL
5.2. Hydraulic connections
By hose with spiral reinforcement or by rigid pipe.
The diameter of the suction piping must never be less than that of
the pump.
Limit the length of the suction pipe and avoid all features that cause
losses of head (tapers, bends, etc.).
This pipe, which will slope upward 2 %, must not let in any air
(See FIG. 1).
If a rigid pipe is used, provide supports or collars so that the pump
does not bear its weight (See FIG. 1).
If the pump is in suction (See FIG. 1) : submerge the strainer (at least
20 cm), if necessary ballast the hose.
TYP
VICTAULIC < 2 kW
VICTAULIC > 2 kW
THREADED < 2 kW
7
50Hz
60Hz
2900
3500
230-400 V
220-380 V / 254-440V
Temperature
Loss of head
20 °C
0,20 mCL
30 °C
0,40 mCL
40 °C
0,70 mCL
50 °C
1,20 mCL
60 °C
1,90 mCL
70 °C
3,10 mCL
80 °C
4,70 mCL
90 °C
7,10 mCL
100 °C
10,30 mCL
PORT ND (TAPPED)
SUCTION
DISCHARGE
2" - (Ø 60.3)
1"1/2 - (Ø 48.3)
3"od - (Ø 76.1)
3"od - (Ø 76.1)
2" - (50-60)
1"1/2 - (40-49)
Tabla de contenido
loading

Este manual también es adecuado para:

Shc 4 kw

Tabla de contenido