CAME BK Serie Manual De Instrucciones página 7

Ocultar thumbs Ver también para BK Serie:
ENGLISH
This control board is powered across
terminals L1 and L2, and is protected by
fuse on the main power line (see table).
Control systems are powered by low
voltage and protected with by a 2A fuse.
The total power consumption of 24 V
accessories must not exceed 20W.
Fixed operating time of 150 seconds.
Safety
Photocells can be connected to obtain:
- Re-opening during the closing cycle
(2-C1);
- Re-closing during the opening cycle
(2-CX, see dip 8-9);
- Partial stop, shutdown of moving gate,
with activation of an automatic closing
cycle (2-CX, see dip 8-9);
- Total stop (1-2), shutdown of gate
movement without automatic closing; a
pushbutton or radio remote control must
be actuated to resume movement;
Note: If an normally closed safety contact
(2-C1, 2-CX, 1-2) is opened, the LED
(n°11) will flash to indicate this fact;
- Obstacle presence detection. When
the motor is stopped (gate is closed,
open or half-open after an emercency
stop command), the transmitter and the
control pushbutton will be deactivated if
an obstacle is detected by one of the
safety devices (for example, the
photocells);
- Safety test function. The control unit
will now check the safety system every
time an opening or closing command is
given (see pag. 13).
The board ZBKE, moreover, integrates
and independently runs a safety function
capable of detecting obstacles that
hinder movement:
during opening
the gate stops and the automatic closure
is activated;
during closure
the gate inverts its direction until it is
completely open, after which it closes
automatically.
Warning! after three consecutive
inversions, the gate will remain open
and automatic closure will be
discontinued. Toclose the gate, use the
radio remote control or the push-button.
Other functions
- Automatic closing: The automatic
closing timer is automatically activated
at the end of the opening cycle. The
preset, adjustable automatic closing time
TECHNICAL DESCRIPTION ZBK - ZBKE MOTHERBOARD
is automatically interrupted by the
activation of any safety system, and is
deactivated after a STOP command or
in case of power failure;
- Partial opening. Opening of the gate to
allow for foot traffic; activated by
connecting to terminals 2-3P and
adjusted with the AP-PARZ. trimmer.
With this function, the automatic closing
can vary in the following way:
1) Dip 12 set to ON: after a partial
opening, the time for automatic closing
functions independently of the
adjustment of the TCA trimmer and of
the position of Dip 1; it is set at 8 seconds.
2) Dip 12 set to OFF: after a partial
opening, the time for automatic closing
is adjustable only if Dip 1 is set to ON.
- Cycle lamp. The lamp which lights the
manoeuvring zone: it remains lit from
the moment the doors begin to open
until they are completely closed
(including the time required for the
automatic closure). In case automatic
closure is not enabled, the lamp remains
lit only during movement (E-EX);
- Courtesy Light. A light that illuminates
the manoeuvring zone; after an opening
command, the light remains on for a
fixed time of 5 minutes and 30 seconds
(E-EX, see page 14);
- "Operator present" function: Gate
operates only when the pushbutton is
held down (the radio remote control
system is deactivated);
- Pre-flashing for 5 seconds, while the
door is opening and closing;
- Master function; the panel assumes all
the command functions when two paired
motors are used (see page 22);
- Slave function; this panel is exclusively
controlled by the "MASTER" (see p.
22);
- Enabling functions of partial-stop or re-
closure during opening; normally-closed
contact (2-CX), select one of the two
functions by setting dip, see selection of
functions;
- Programming the calibration of the
electronic opening and closing limit
switches for the ZBKE panel (see p. 21),
Type of command:
- open-close-reverse by button and
transmitter;
- open-stop-close-stop by button and
transmitter;
- open only by transmitter.
- Trimmer AP.PARZ. = Partial opening:
1" to 14";
- Trimmer TCA = Automatic closing
time: 1" to 150";
P
- the opening of the unblock panel arrests
- Shut off the mains power and disconnect
- 8 -
Adjustments
B
K
/
B
K
E
1
2
0
0
1
8
0
0
2
2
0
0
o
w
r e
s
u
p
p
y l
2
3
0
V
. a
. c
L
n i
e
u f
s
e
8
A
Important:
the motor.
the batteries before servicing the inside
of the unit.
B
K
/
B
K
E
1
2
1
0
1
8
1
0
2
2
1
0
1
1
0
V
. a
. c
1
5
A
loading