Remaining Hazards - Scheppach Tisa 3.0 Traducción De La Instrucción De Original

Sierra circular de mesa
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
sponsibility for any resulting damages.
• The scheppach machine may only be used with origi-
nal accessories and original tools made by the manu-
facturer.
• Any other use exceeds authorization. The manufacturer
is not responsible for any damages resulting from un-
authorized use; risk is the sole responsibility of the
operator.
m Use only as authorized
CE tested machines meet all valid EC machine guidelines as
well as all relevent guidelines for each machine.
1 The machine has been built in accordance with state-
of-the-art standards and the recognized safety rules.
Nevertheless, its use may constitute a risk to life and
limb of the user or of third parties, or cause damage to
the machine and to other material property.
2 The scheppach circular saw bench is constructed exclu-
sively for the sawing of wood. The required saw blade
should be inserted according to the cut type and the
wood type (solid wood, chip board or plywood).
3 The machine must only be used in technically perfect
condition in accordance with its designated use and the
instructions set out in the operating manual, and only
by safety-conscious persons who are fully aware of the
risks involved in operating the machine. Any functional
disorders, especially those affecting the safety of the
machine, should terefore be rectified immediately.
4 When used in enclosed rooms, the machine must
be connected to a vacuum exhaust unit. Use the
scheppach vacuum exhaust unit ha 3200 or ha 2600
to remove matchwood or saw dust. The vacuum support
flow rate must be 20 m/s. Subatmospheric pressure
1200 Pa.
5 The scheppach automatic switching unit is available
as a special accessory. The vacuum exhaust unit auto-
matically switches on after a 2-3 second delay after
the machine tool is turned on. This avoids overloading
the circuit fuse. After turning off the machine tool,
the vacuum exhaust unit remains on for an additional
3-4 seconds and is then automatically switched off.
Remaining dust is thereby removed by vacuum exhaust,
as required by German regulations governing hazard-
ous materials. This results in savings in electricity
consumption and reduces noise levels, as the vacuum
exhaust unit is on only during machine tool operation.
6 For work in commercial spaces, the scheppach dust
remover woova 7 must be used. Do not remove or shut
off vacuum exhaust systems or dust removers while
machine tools are operating.
7 Any other use exceeds authorization. The manufacturer
is not responsible for any damages resulting from un-
authorized use; risk is the sole responsibility of the
operator.
8 The safety, work and maintenance instructions of the
manufacturer as well as the technical data given in
the calibrations and dimensions must be adhered to.
9 Relevant accident prevention regulations and other,
generally recognized safety-technical rules must also
be adhered to.
10 The scheppach Table Circular Saw may only be used,
maintained, and operated by persons familiar with and
instructed in its operation and procedures. Arbitrary
alterations to the machine release the manu facturer
from all responsibility for any resulting damages.
11 The scheppach Table Circular Saw may only be used
with original accessories and saw blades from the
manufacturer.
m Remaining hazards
The machine has been built using modem technology in
accordance with recognized safety rules. Some remaining
hazards, however, may still exist.
• The rotating saw blade can cause injuries to fingers
and hands if the work piece is incorrectly fed.
• Thrown work pieces can lead to injury if the work piece
is not properly secured or fed, such as working with-
out a limit stop.
• Noise can be a health hazard. The permitted noise lev-
el is exceeded when working. Be sure to wear personal
protective gear such as ear protection.
• Defective saw blades can cause injuries. Regularly in-
spect the structural integrity of saw blades.
• The use of incorrect or damaged mains cables can lead
to injuries caused by electricity.
• The operating instructions supplied with the special
accessories must be observed and carefully read when
scheppach special accessories are used.
• Even when all safety measures are taken, some re-
maining hazards which are not yet evident may still
be present.
• Remaining hazards can be minimized by following the
instructions in „Safety Precautions", „Proper Use" and
in the entire operating manual.
Tisa 3.0
Scope of delivery
Technical Data
Overall length with table
extension
Overall length without table
extension
Overall width
Overall height
Table size
Circular saw bench with motor
and switch
Feet and cross-struts
Saw blade Ø 315 mm
Dust bag connector
Covering cap
Suction tube
NW 50 x 2 m
Splitting wedge
Longitudinal stop
with angle bar
Table extension
Saw blade key
Push stick
Push stick
Operating instructions
Special accessories –
page GB16
1265 mm
850 mm
690 mm
1095 mm
790 x 590 mm