General Information; Recommended Pool Water Levels - Davey DPLGEU Instalación E Instrucciones De Funcionamiento

Cloración y química de piscinas completas
Ocultar thumbs Ver también para DPLGEU:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 313
pH High Warning
PH High
pH High Alarm
PH HIGH
ORP Low Warning ORP LOW
ORP High Warning ORP HIGH
ORP High Alarm
ORP HIGH
ORP Low Alarm
ORP LOW
Low Flow Alarm
FLOW LOW
SETUP
Setup Incomplete
INCOMPLETE
ADDITIONAL INFORMATION:
LED = solid is a warning, = flashing is an alarm
Clearing probe alarms are done automatically when readings are within limits.
Probe alarms are triggered only if there is flow, and will remain on until cleared

10. GENERAL INFORMATION

10.1 RECOMMENDED POOL WATER LEVELS

POOL
Free Chlorine
WATER
(ppm)
BALANCE
Ideal
reading
1.5 - 3
/ range
Increase
output of
sanitiser.
To increase
Add chlorine.
Increase
filtration time.
Decrease
output of
To decrease
sanitiser.
Decrease
filtration time.
Frequency
Weekly
of testing
Figure 10.1
If a pH reading greater than
or equal to 0.2pH points more
than set point is recorded.
If a pH reading of 8 or above
is recorded.
If an ORP reading greater
than or equal to 15mV points
less than set point is recorded.
If ORP reading is greater than
or equal to 15mV more than
set point.
If the ORP reading of 800mV
or higher is recorded.
If an ORP reading is 535mV
or below.
A flow rate below 3.6m3/h
(60L/min).
The first time set-up process
was not completed.
Total
pH
Alkalinity TA
(ppm)
Concrete &
tiled pools
7.4-7.6
80 - 150
Other surfaces
7.2-7.4
Add Soda
Add Buffer
Ash (Sodium
(Sodium
Carbonate)
Bicarbonate)
Add
Add
Hydrochloric
Hydrochloric
Acid or Dry
Acid
Acid
Weekly
Weekly
50
Will clear automatically once pH is
within 0.2pH units away from set point.
Will clear automatically once pH is
below 8.
Will clear automatically once ORP is
within 15mV of set point.
Will clear automatically once ORP is
within 15mV of set point.
Will clear automatically if once ORP
reading is lower than 800mV.
Will clear automatically once ORP is
above 535mV.
Fault is cleared instantly and automatically
once correct flow is detected.
Select FACTORY RESET and
complete the process.
Calcium
Stabiliser -
Hardness
Cyanuric Acid
(ppm)
(ppm)
25-50ppm
Concrete &
(15-25ppm if
tiled pools
used with an
200-275
ORP controller)
Other surfaces
100-225
Not to be used
in indoor pools.
Add Calcium
Add Cyanuric
Chloride
Acid
Partially drain
& refill pool
Partially drain
with lower
& refill pool to
hardness
dilute
water to Dilute
Weekly
Regularly
Recommended
salt Levels
(ppm)
Depends on
the model of
your EcoSalt2
Add salt
Partially drain
& refill pool to
dilute
Regularly
Tabla de contenido
loading

Tabla de contenido