Figure 6.13
• Once complete, the display will instruct you to remove the probe (refer Figure 6.14).
Figure 6.14
• The probe can then be removed from the pH calibration solution and installed into the probe and
injection housing;
• On the probe and injection housing, under each of the 3 x probe locking nuts, is an o-ring and washer
(refer Figure 6.15). Remove the first probe locking nut on the housing (where it's marked pH);
• Carefully slide the probe locking nut, then the washer, then the o-ring, onto the probe
(refer Figure 6.16);
• The o-ring should not be lubricated when being fitted, please ensure it is completely dry.
ph calibration:
in progress . . .
58
ph calibration:
complete
remove probe
Figure 6.15
22