Adjusting Orp Set Point; On The Davey Lifeguard Control Panel - Davey DPLGEU Instalación E Instrucciones De Funcionamiento

Cloración y química de piscinas completas
Ocultar thumbs Ver también para DPLGEU:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 313
Figure 8.27
This can also be observed from the dashboard of the Davey Lifeguard app (refer Figure 8.28).

8.2.1. Adjusting ORP set point

The factory default ORP set point is 650mV, however you may wish to change this once the Lifeguard is
installed. It should be noted that Chlorine's effectivity is greatly influenced if pH levels are too high, or too
low. Davey recommends following the pool levels shown in section 10. Adjustments to pH set point can
be made as follows.

8.2.1.1. On the Davey Lifeguard control panel

• From the HOME SCREEN, press the
main menu (Figure 8.29);
Figure 8.29
• Press the
system on
slt 1782
orp
650 ph 7.4
Figure 8.28
menu/setting select button. This will now show the
main:
-> modes
settings
maintenance
menu up/down button to scroll down to settings (Figure 8.30);
100%
t 19°c
38
Tabla de contenido
loading

Tabla de contenido