9.4 SPA & COVER MODE (SIMULTANEOUS)
Should it be necessary to run SPA MODE and COVER MODE simultaneously, the chlorinator cell duty
cycle is only reduced by 80% That is, the cell duty cycle isn't reduced by 80%, followed by a further 80%.
The HOME SCREEN display will toggle between showing COVER and SPA.
9.5 WINTER MODE (for use if NO ORP probe is connected)
A pool's exposure to UV contributes significantly to the pool's total chlorine demand. Ie the amount of
chlorine the pool uses. Bather load is also a significant contributor to the pool's total chlorine demand.
In winter, the pool's chlorine demand is typically far less. Unless otherwise altered, if the chlorinator cell
is producing chlorine, it is producing at 100% current (output). WINTER MODE reduces the cell's current
(output) to 85%.
For example:
• If the EcoSalt2 is on for 10 hours per day, the CHLORINE OUTPUT is set to 100%, the WINTER
MODE is off: the EcoSalt2 cell duty cycle is 10 hours. The chlorinator cell current will be operating at
100% capacity;
• If the EcoSalt2 is on for 10 hours per day, the CHLORINE OUTPUT is set to 100%, but the WINTER
MODE is on: while the EcoSalt2 cell duty cycle is still 10 hours, the chlorinator cell current will only be
operating at 85% capacity.
WINTER MODE can only be selected from the menu if ORP probe is not connected.

9.6 WARNINGS AND ALARMS

Message
Warning or Alarm
on Davey
Lifeguard
Low Salt Warning SALT LOW
Low Salt Alarm
SALT LOW
Check Pool Chem
CHECK POOL
Alarm
CHEM
Flashing icons
WiFi Disconnected
Warning
pH Low Warning
PH LOW
pH Low Alarm
PH LOW
Cause for Alarm
Low Salt Models - salt reading
of 1500ppm or below.
Regular Models - salt reading
of 3000ppm or below.
Low Salt Models - salt reading
of 1200ppm or below.
Regular Models - salt reading
of 2500ppm or below.
Dirty cell or inaccurate pool
chemistry.
Davey Lifeguard is
disconnected from WiFI.
If a pH reading is great than or
equal to 0.2pH units less than
set point is recorded.
If a pH reading of 6.8 or below
is recorded.
49
How alarm is cleared
Once the Davey Lifeguard registers
a salt concentration within range the
warning will clear.
Once the Davey Lifeguard registers a
salt concentration within range the alarm
will clear and the Davey Lifeguard will
return to normal operation.
Cell will have turned off. Check cell
is clean and clean if required. Have a
full analysis of water done and make
sure that all parameters are withing
the recommended range in the table
(Figure 10.1 next page). Press the
SELECT button to clear the alarm.
Davey Lifeguard will attempt to re-
connect itself to WiFi. If this does not
happen automatically press and hold
the SELECT button for 5 seconds
and until both icons will toggle to
re-establish internet connection.
Connection is established when both
icons are stable.
Will clear automatically once pH is
within 0.2pH units away from set point.
Will clear automatically once pH is
raised above 6.8.
continued next page...