en
�� | BS� ���� | Manual mode (normal operation)
5.
Manual mode (normal operation)
i
Manual mode is required for the performance of
single wheel measurements or for noise simulation.
Principal features:
R
Test sequence can be selected by user.
R
Measurements must be started manually.
R
Measurement results can be stored.
5.�
Brake dynamometer Test sequence
i
The weight is required for calculation of deceleration. The weight can be entered or measured as follows:
$
Manual entry using remote control unit (refer to Section 5.3.1).
Manual weight entries have precedence over measured weight values.
$
Axle load scales in brake dynamometer (special accessory).
Use is automatically made of the measured weight if the weight has not been entered manually.
Step
1. Check prerequisites:
R
No vehicle on brake dynamometer!
R
Test routine selected.
2. Drive vehicle onto dynamometer.
¶
With the axle to be measured first and
keeping the vehicle straight.
¶
Disengage gear.
¶
Release brake pedal.
!
If the vehicle is not straight on the
set of rollers, it will slide off to the
side. Counter-steer until the vehicle
returns to straight position on the set
of rollers. Measurement is not to be
started before this has been done.
i
It may be necessary to drive off the set
of rollers and then drive the vehicle
back on.
|
1 691 506 010
2009-05-25
R
Measurement results can be printed out.
R
Single wheel measurements are possible.
5.1
Mode activation and deactivation
Manual mode is the standard factory default setting.
Following termination of other modes, the BSA 42xx re-
turns to manual mode.
�nalog display
Remote
control unit
Result / �nalog display
? Warning lamp OFF.
? LCD:
Drive-on prompt.
? Axle to be measured is positioned
on set of rollers.
? If use is being made of axle load
scales (special accessory):
LCD:
Axle load in kilograms.
Robert Bosch GmbH