Short Loop Test; To Locate A Break In The Boundary Wire - Petsafe PRF-3004XW-20 Manual De Funcionamiento

Limitador de zona con cable para perros difíciles de adiestrar
Ocultar thumbs Ver también para PRF-3004XW-20:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74

Short Loop Test

The Short Loop Test is a simple test to determine if each component (Fence Transmitter, Receiver Collar and Boundary
Wire) is functioning properly.
1. Disconnect the Boundary Wire.
2. Cut approximately 3 m (10 ft) of unused Boundary Wire and connect it to the Boundary Wire Terminals.
3. Spread the Boundary Wire out into a circle. Set the Boundary Control Switch to B.
4. Set the Boundary Width Control knob to 10.
5. If the Loop Indicator Light is not lit, then your Fence Transmitter is not functioning properly. Contact the Customer Care
Centre.
6. If the Loop Indicator Light is lit, disconnect one end of the Boundary Wire from the Boundary Wire Terminal.
7. If the loop alarm does not sound, the Fence Transmitter needs to be replaced. Contact the Customer Care Centre.
8. If the loop alarm does sound, plug the Boundary Wire back into the Boundary Wire Terminal.
9. Hold the Test Light Contacts to the Receiver Contact Points. Hold the Receiver Collar next to the 3 m (10 ft) length of
Boundary Wire. The Receiver Collar should beep about one foot away from the Boundary Wire. The Test Light should
then flash as you hold the Receiver Collar closer to the Boundary Wire.
10. If Receiver Collar does not beep and the Test Light does not flash, replace the battery in the Receiver Collar. If it still
does not beep and the Test Light does not flash, contact the Customer Care Centre.
11. If the Receiver Collar beeps, there may be a complete or partial break in the Boundary Wire. See the "To Locate a Break
in the Boundary Wire" section.

To Locate a Break in the Boundary Wire

Please follow these steps in determining where you have a break in your Boundary Wire:
1. Locate your original splice(s) and verify they have a good, solid connection.
2. Check your garden to determine any possible damage to the Boundary Wire (e.g. recent digging, aerating, rodent
burrowing, or any other noticeable disturbance in your yard next to the Boundary Wire).
If you still cannot find the break in the Boundary Wire, there are two options for locating it:
Option 1: Contact the Customer Care Centre to purchase a Wire Break Locator that will locate the break in the Boundary
Wire.
Option 2: Follow the procedure below:
1. Unplug the Fence Transmitter.
2. Connect both ends of your twisted Boundary Wire to one Boundary Wire Terminal.
3. Measure and cut a Test Wire which is half the length of your total Boundary Wire footage.
4. Connect one end of Test Wire to the other Boundary Wire Terminal.
5. Locate the halfway point of your boundary and cut the Boundary Wire.
6. Splice the other end of the Test Wire to either side of your Boundary Wire where you cut
it in half.
7. Plug in the Fence Transmitter and check the Loop Indicator Light. If the Loop Indicator
Light is on, you can assume the break is in the other half of the Boundary Wire.
8. If the Loop Indicator Light did not come on, you may assume there is a break in this
portion of the Boundary Wire. However, there is a small chance of having more than one
break in your system. Be sure to check both halves of your entire loop.
9. Replace the damaged Boundary Wire with new Boundary Wire.
10. Reconnect the Boundary Wire to the Fence Transmitter.
11. Check the Loop Indicator Light. If the Loop Indicator Light is on, test the system with the Receiver Collar.
petsafe.com
Test
Wire
23
Tabla de contenido
loading

Tabla de contenido