Additional Boundary Wire; Connect The Wires To The Fence Transmitter - Petsafe PRF-3004XW-20 Manual De Funcionamiento

Limitador de zona con cable para perros difíciles de adiestrar
Ocultar thumbs Ver también para PRF-3004XW-20:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
3D
1 cm
(
/
in)
3
8

Additional Boundary Wire

Extra direct burial Boundary Wire can be purchased in 150 m (500 feet)
spools at the store where you purchased the kit or through the Customer
Care Centre.
Note: When adding Boundary Wire, it must act as a continuous loop.
The table at right indicates the approximate length of Boundary Wire
needed for a square, Single Loop layout. Length will vary due to the
amount of twisted wire and layout used. Remember that a Double
Loop will require twice as much wire.
__________________________________________________

Connect the Wires to the Fence Transmitter

Step
4
Boundary Wire
1. Run the Boundary Wire to the Fence Transmitter through a window, under a
door, through a crawl space vent, or any other appropriate available access. You
can also drill a hole through your wall.
2. Strip the ends of the Boundary Wire approximately 1 cm (
3. Insert the Boundary Wires into the Boundary Wire Terminals on the Fence
Transmitter. Make sure the wires do not touch each other at the terminals.
4. Turn the Boundary Width Control knob to 10. This will set the Warning Zone
at the maximum width.
5. Plug the Power Adapter into the Power Socket and a working outlet. The
Power Adapter comes with the North American plug installed and additional
plugs for the UK, Europe, and Australia. To change the plug:
a. Push in the tab on the Power Adapter and remove the plug by sliding it off as
shown (4B).
b. Slide the proper plug for your electrical outlet onto the Power Adapter
as shown (4C).
6. The Power Light and Loop Indicator Lights should come on. If this
does not happen, see the "Troubleshooting" section.
Do not install, connect, or remove your system during a lightning storm. If the storm is close enough for you
to hear thunder, it is close enough to create hazardous surges.
Risk of electric shock. Use the fence transmitter indoors in a dry location only.
If possible, DO NOT use an outlet protected with a Residual Current Device (RCD) or Ground Fault Circuit
Interrupter (GFCI). The fence system will function properly, but in rare cases, nearby lightning strikes may cause the
RCD or GFCI to trip. Without power, your pet may be vulnerable to escape. You will have to reset the RCD or GFCI to
restore power to the system.
For added protection for the Fence Transmitter when unused for long periods of time or prior to
thunderstorms, disconnect the Loop Boundary Wires and unplug the Power Adapter from the outlet. This will prevent
damage to the Transmitter due to surges.
10
3E
1 cm
(
/
in)
3
8
1
(4A)
3F
/
").
3
8
petsafe.com
3G
Area to be enclosed
Approximate wire
Ar
Ac
Ha
M
10
1/4
0.10
127
13
1/3
0.13
146
20
1/2
0.20
180
40
1
0.40
255
80
2
0.80
360
200
5
2
570
400
10
4
854
4A
Loop Indicator
Light
Power Light
Power
Boundary Width
Jack
Control
4B
4C
length required
Ft
415
480
590
835
1180
1870
2800
}
Boundary Wire
Terminals
Tabla de contenido
loading

Tabla de contenido