Prince Castle 411-SD Serie Manual Del Usuario página 11

Tabla de contenido
Problem
Lower platen under heating.
Lower platen over heating.
Lower probe open.
Upper platen under heating.
Upper platen over heating.
Upper probe open.
Both platens under heating.
Both platens over heating.
Both probes open.
Problem
Lower probe circuit failure.
Upper probe circuit failure.
Both probe circuits failure.
Problem
Lower platen over heating.
Lower probe open.
Upper platen over heating.
Upper probe open.
Both platens over heating.
Both probes open.
Diagnostic Codes
EO7
E7O
E77
Diagnostic Codes
EO8
E8O
E88
Diagnostic Codes
EO9
E9O
E99
11
Corrective Action
Go to E01, E02 and E04 corrective action.
Go to E01, E20 and E40 corrective action.
Go to E11, E22 and E44 corrective action.
Corrective Action
Go to E02 corrective action, replace the item
indicated by the test result.
Go to E20 corrective action, replace the item
indicated by the test result.
Go to E22 corrective action, replace the item
indicated by the test result.
Corrective Action
Go to E01 and E08 corrective action.
Go to E01 and E80 corrective action.
Go to E11 and E88 corrective action.