Siemens SITRANS FUS1010 Guia De Inicio Rapido página 12

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Quick Start Guide
4. Application Data Entry
Use this menu cell to enter the
number of pipe diameters
between the upstream
configuration and the
transducer installation.
PIPE CONFIGURATION OPTION LIST DEFINITIONS
Fully Developed
1 Elbow
Dble Elbow +
Dble Elbow -
Valve
Expander
Reducer
Norm Entry
Header Inlet
Intrusions
12
Flowmeter Programming
Liquid Class
Press the <Down Arrow> and scroll to [Application Data].
Press the <Right Arrow> to select [Liquid Class].
Press the <Right Arrow> again and scroll to desired liquid.
Press <ENT> to save selection.
Siemens
2 Channel [1]
Select Liquid Class from Liquid Table
Liquid Class
UniMass Tables
Temp. Range
Pipe Config
Anomaly Diams
Application Data
Pipe Configuration
Scroll down to [Pipe Config] and press the <Right Arrow>.
Select a configuration that approximates the conditions upstream of your transducer
mounting location. (Refer to the definitions below.)
Press <ENT> to save the selection.
Siemens
Disignate Pipe Shape Near Transducers
Liquid Class
UniMass Tables
Temp. Range
Pipe Config
Anomaly Diams
Application Data
Press the <Left Arrow> and return to the main menu.
Fully Developed flow, as would be expected for very long straight pipe runs or installation down-
stream of a flow condition.
Single 90 degree Elbow upstream of transducer installation.
Double out-of-plane Elbows upstream of transducer installation.
Double in-plane Elbows upstream of transducer installation.
Not available at this time.
Pipe expansion upstream of transducer installation.
Pipe reduction upstream of transducer installation.
Not available at this time.
Header or pipe manifold upstream of transducer installation.
Not available at this time.
ABC
Water 20C/68F
Disabled
-40F to 250F
Fully Developed
10
2 Channel [1]
ABC
Water 20C/68F
Disabled
-40F to 250F
Fully Developed
1 Elbow
Dbl Elbow +
Dbl Elbow -
Valve
Expander
Reducer
Norm Entry
Header Inlet
Intrusions
Select from list.
Use this menu cell to select
the pipe configuration that
most accurately represents
the upstream pipe condition.

Hide quick links:

Tabla de contenido
loading

Tabla de contenido