Using Your Ceiling Fan - LUCCI AIRFUSION CLIMATE III Manual Del Usario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
Airfusion Climate III Installation Instructions
REMOTE CONTROL (Fig.12)
1. Open the battery compartment cover by removing the securing screw and insert 2 x AAA battery. Note the
correct battery polarity (+/-) when inserting the battery, and then replace the cover and secure with the screw.
2. Test the remote by pressing and hold any button. A red LED will be lit up at the top of the remote to indicate
that there is power to the remote and it is ready for use to control the fan.
3. Follow the guide below to operate the fan and learn the functions.
REPAIRING THE FAN RECEIVER & REMOTE PAIRING
NOTE: The pairing of the remote and receiver has been done at the factory.
When the ceiling fan is installed, pairing the fan receiver and remote is NOT required.
Should the remote and receiver lose control after installation or during use, the pairing of the remote and the
receiver must be repaired. Below are the operating symptoms and method to repair the pairing of the DC
ceiling fan remote and receiver.
Issues:
Loss of control - Fan is only running at high speed after installation
Loss of control - No reverse function after installation
Loss of control - Remote cannot communicate with the receiver
Solution:
Switch off the main power of ceiling fan.
Switch on the main power of the ceiling fan. Press and hold the On/Off button on the remote for 5 seconds
within 30 seconds after switching on. There will be a notification 'beep' sound from the receiver to indicate
that the paring process is successful.
Turn on and select the different speed of the ceiling fan to check the operation of the fan.