INDICATIONS ON THE DISPLAY (FIG. 3, PAGE 4)
Start up display
(Shown for 2 seconds)
SL424E
Indicates the dip-switch setting memorisation stage
Alarm indications
System not programmed
You have to enter the programming mode to program the
system
Out of position
ing
commands received (TA, TC, TAL or TD) will automatically start this
procedure.
Caution! The gate moves automatically without waiting for
Memory parameter error
Carries on with the system programming and if the error remains it will
switch off the battery and mains power and reset the programmer. If
the error persists contact the after sales service.
Block during programming
This happens when an N.C. contact is activated (TB, FTCI, FTCS,
CSP) during encoder programming or automatic repositioning. Once
the passive state of the security devices has been reset the gate will
start moving again automatically. It also happens if a blackout occurs
during programming.
Safety device test error
Check the condition of the safety devices and make sure that the alarm cuts
in when an obstacle interferes with the beam (the relative LED will switch
off). In case of anomalies replace the damaged safety device or bridge the
contact and deactivate the safety test (dip 7, 8).
Motor feed error
This occurs when the programmer sends a command to the motor and
nothing happens (the motor doesn't move). Check the motor faston
another opening or closing command. If the motor still doesn't move
you are faced with either a mechanical problem or a problem with the
programmer.
Encoder count error
If this error occurs during normal motor operation it means that there
is a problem with one of the encoder signals. Check the relative con-
nections and carry out automatic repositioning (pag. 18).
Encoder direction error
The gate movement direction is different from the encoder setting (eg.
the gate moves in the closing direction while the program is carrying
out the opening stage). Check the motor power supply connections.
Current sensor error
When the gate is not moving this symbol means there is a problem
with the current sensor.
_11
automatic reposition-
rPS
1
F2
F3
Operational indications
Pause time programming
Automatic programming under way
Opening stage
Block
Pause for automatic reclosing (if activated)
Closing stage
Current sensor updating (only during programming)
Opening + compensation sensor
Closing + compensation sensor
Test mode
Battery mode with a fully charged battery
Battery mode with an undercharged battery
Discharged battery
When the battery is almost completely flat the symbol
appear on the display and the motor and commands will be
blocked.
SELECTING THE SECURITY CONTACT
SC
TB
FTCS
0
N.C.
1
N.C.
2
N.C.
3
N.C.
4
N.C.
8.2 kΩ
5
N.C.
8.2 kΩ
6
N.C.
8.2 kΩ
7
N.C.
8.2 kΩ
8
8.2 kΩ
9
8.2 kΩ
A
8.2 kΩ
B
8.2 kΩ
C
8.2 kΩ
8.2 kΩ
D
8.2 kΩ
8.2 kΩ
E
8.2 kΩ
8.2 kΩ
F
8.2 kΩ
8.2 kΩ
22
FTCI
CSP
N.C.
N.C.
N.C.
N.C.
N.C.
8.2 kΩ
N.C.
8.2 kΩ
N.C.
N.C.
8.2 kΩ
8.2 kΩ
N.C.
N.C.
N.C.
8.2 kΩ
8.2 kΩ
N.C.
8.2 kΩ
8.2 kΩ
N.C.
N.C.
N.C.
N.C.
N.C.
8.2 kΩ
N.C.
8.2 kΩ
N.C.
N.C.
8.2 kΩ
8.2 kΩ
N.C.
N.C.
N.C.
8.2 kΩ
8.2 kΩ
N.C.
8.2 kΩ
8.2 kΩ
will