• Set the main operating parameters (e.g. installation right/left) in the options menu.
• If you have safety devices working with 8.2k contacts select the correct setting from the safety device menu.
• Before programming the gate travel distances select the correct motor in the "Motion" menu.
OPTIONS
SAFETY DEVICES
MOTION
Arrow
DISPLAY
to
CALENDAR
scroll
REMOTE
"PROG/OK"
to confirm
SET TIME
08:00
SET DATE
"PROG/OK"
23-12-13
to change
the value
SET EVENTS
SET TIME
08:00
"PROG/OK"
SET DATE
to change
23-12-13
the value
SET EVENTS
SET TIME
08:00
SET DATE
23-12-13
"PROG/OK"
SET EVENTS
to confirm
EVENT 0
SET DATE
MO-SU 08-10 TA 1
23-12-13
EVENT 1
SET EVENTS
MO-SU 08-10 TA 1
EVENT 2
EVENTS: ON/OFF
MO-FR 10-08 TA 0
EXIT
SET EVENTS
"PROG/OK"
to return to
'calendar/remote'
EVENTS: ON/OFF
EXIT
Events On/Off:
Setting one of the radio channels to 'events on/off' will allow you to activate/deactivate the events via radio control. Activation will be indicated by
the warning light and indicator light flashing for 6 seconds. Deactivation will be indicated by the lights flashing for 3 seconds.
Language choice:
• Press the right and left
buttons simultaneously to
enter the language
submenu.
• Press the right and left
buttons to change the
language: Italian to
English.
• Press the "PROG/OK"
button to con rm the
choice.
Operational indications
Pause time programming or
PAUSE
pause
TB FI
TA TD
reclosing (if activated)
FS CP
TC TAL
AUTO PROG
Automatic programming
TB FI
TA TD
under way
FS CP
TC TAL
OPENING
TB FI
TA TD
Opening stage
FS CP
TC TAL
STOP OPENING
Block during opening
TB FI
TA TD
FS CP
TC TAL
CLOSING
TB FI
TA TD
Closing stage
FS CP
TC TAL
STOP CLOSING
TB FI
TA TD
Block during closing
FS CP
TC TAL
OPTIONS
SAFETY DEVICES
MOTION
Arrow
Arrow
DISPLAY
to scroll
to exit
CALENDAR
REMOTE
"PROG/OK"
to confirm
"PROG/OK"
MEMORISE
to confirm
CANCEL
CLEAR ALL MEMORY
CHANNEL FUNCTION
EXIT
MEMORISE
"PROG/OK"
CANCEL
to confirm
CLEAR ALL MEMORY
CHANNEL FUNCTION
EXIT
MEMORISE
CANCEL
"PROG/OK"
CLEAR ALL MEMORY
to confirm
CHANNEL FUNCTION
EXIT
MEMORISE
CANCEL
CLEAR ALL MEMORY
"PROG/OK"
CHANNEL FUNCTION
to confirm
EXIT
MEMORISE
CANCEL
CLEAR ALL MEMORY
CHANNEL FUNCTION
EXIT
PROGRAM
PROGRAM
TB FI
TA TD
TB FI
TA TD
FS CP
TC TAL
FS CP
TC TAL
TB FI
TA TD
00.000.007
FS CP
TC TAL
07-06-13 15.35
OUT OF POS
press both arrows
simultaneously to enter
the language submenu
STOP PROG
TB FI
TA TD
ITALIANO
FS CP
TC TAL
FRANÇAIS
AUTO PROG
ENGLISH
NEDERLANDS
DEUTSCH
ESPAÑOL
TB FI
TA TD
FS CP
TC TAL
"PROG/OK" to confirm
SAFETY ERROR
TB FI
TA TD
FS CP
TC TAL
for
automatic
ERROR MOT
TB FI
TA TD
FS CP
TC TAL
ERROR ENC
TB FI
TA TD
FS CP
TC TAL
ERROR DIR
TB FI
TA TD
FS CP
TC TAL
ERROR SENS
TB FI
TA TD
FS CP
TC TAL
ACT. SAFETY EDGE
TB FI
TA TD
FS CP
TC TAL
ACTIVE SENSOR
PRESS the
MEMORISE
transmitter
[Nr...]
channel
to memorise
* * * * * * * * * * * * * * *
*
*
* ACTIVATION 1
*
*
*
* * * * * * * * * * * * * * *
PRESS the
CANCEL
transmitter
[Nr...]
channel
* * * * * * * * * * * * * * *
to memorise
*
*
* ACTIVATION 1
*
*
*
* * * * * * * * * * * * * * *
EXIT
* * * * * * * * * * * * * * *
CANCEL
*
*
* ALL MEMORY ? *
PRESS ok to
* * * * * * * * * * * * * * *
cancel all
memory
OK
or press exit
CHANNEL A
channel function A
CHANNEL B
"PROG/OK"
to change
channel function B
the value
CHANNEL C
channel function C
Note: 10
CHANNEL D
channel function D
EXIT
Alarm indications
Flashing on the display. You have to enter the programming mode to program the system.
During normal operation it indicates that the "automatic repositioning" procedure is about to
take place. In this case any commands received (TA, TC, TAL or TD) will automatically start
this procedure.
This happens when an N.C. contact is activated (FI, FS, CP) during encoder programming or
automatic repositioning. Once the passive state of the security devices has been reset the gate
will start moving again automatically. It also happens if a blackout occurs during programming.
Safety device test error. Check the condition of the safety devices and make sure that the
alarm cuts in when an obstacle interferes with the beam (indication white characters on a black
background). In case of anomalies replace the damaged safety device or bridge the contact
and deactivate the safety test (option menu).
This occurs when the programmer sends a command to the motor and nothing happens (motor
doesn't move). Check the Faston connections of the motor and the condition of the fuses "F3",
"F4" and then give another opening or closing command. If the motor still doesn't move you are
faced with either a mechanical problem or a problem with the programmer.
Encoder count error. If this error occurs during normal motor operation it means that there is a
problem with the encoder signal. Check the relative connections and carry out automatic
repositioning.
Encoder direction error. The gate movement direction is different from the encoder setting (eg.
the gate moves in the closing direction while the program is carrying out the opening stage).
Check motor power supply connections.
Current sensor error. When the gate is not moving this symbol means there is a problem with
the current sensor.
When the safety edge intervenes the gate will automatically invert for a few moments, both in the
closing as well as the opening direction, to free the obstacle it will then stop for 3 minutes and
then continue moving in the original direction after a 10 second pre ashing period has elapsed.
When the sensor intervenes the gate will automatically invert for a few moments, both in the
closing as well as the opening direction, to free the obstacle it will then stop for 3 minutes and
then continue moving in the original direction after a 10 second pre ashing period has elapsed.
19
PRESS the
MEMORISE
the same
[Nr...]
transmitter
channel
* * * * * * * * * * * * * * *
* * * * * * * * * * * * * * *
again
*
*
*
* ACTIVATION 2
*
*
*
*
*
* * * * * * * * * * * * * * *
* * * * * * * * * * * * * * *
PRESS the
CANCEL
the same
[Nr...]
transmitter
channel
* * * * * * * * * * * * * * *
* * * * * * * * * * * * * * *
again
*
*
*
* ACTIVATION 2
*
*
*
*
*
* * * * * * * * * * * * * * *
* * * * * * * * * * * * * * *
* * * * * * * * * * * * * * *
* CANCELLING
*
*
*
* * * * * * * * * * * * * * *
MEMORISE
[Nr...]
*
CODE
*
MEMORISED
*
CANCEL
[Nr...]
*
CODE
*
CANCELLED
*