Intended Use
This unit is intended to be used in both the dental office and laboratory to manufacture thermoplastic appliances.
PackagIng contents
• Power Cable
• Glass Pellets
• 4mm Allen Wrench
settIng UP
The Essix
SelectVac
®
®
1. Handles: Attach the small handle to the front of the heater cover. Install the pivot brake. Then, screw the sheet support handle
(the knob with the label) into the right hand side of the machine. Turn it towards you to lower the plate and start the vacuum.
The blank knob screws into the left hand side and remains fixed during operation.
2. Placement: The Essix
electrical outlet. Keep area free from moisture and excessive heat. caUtIon: The unit should not be placed closer than 6"
from walls, cabinets or other equipment while in operation because of the temperature emitted from the heater. Under no
circumstances should this unit be operated while located under or in a cabinet. Do not block bottom vent.
3. electric cord: Always ensure the machine is set up for the proper voltage (110V or 220V). Plug the female end of the cord
into the electrical inlet located on the back of the unit and the male end into a properly grounded electrical outlet. The unit's
power cord should not be placed near the heater or any other hot surface. When setting up the unit, do not block the inlet
power cord so the unit can be disconnected if needed.
Parts IdentIfIcatIon
figure 01
01 Heating unit handle
02 Heating unit
03 Sheet support handle
04 Sheet support
05 Column
06 Combined cast rack (cup/flat type)
02
01
09
10
2
ENG
• Cast Rack
• User Manual
• Essix
®
SelectVac
requires minimal preparation for use. A few simple steps are necessary before operating the unit:
SelectVac
should be placed on a flat, open counter, within 4' of a standard properly grounded
®
®
07 Vacuum chamber
08 Main switch
09 Sheet lock handle
10 Digital timer
11 Rotary sheet support handle
12 Pivot Brake
general Information
Intended Use ..............................................................2
Setting Up ...................................................................2
Troubleshooting ..........................................................3
Exploded View ............................................................5
®
Machine
13
12
03
04
11
05
06
07
08
figure 02
13 Rotating lock screw
14 Sheet lock
15 Side lock pins
14
15