Maintenance And Cleaning; Cleaning The Device; Regular Tasks - Oase ProfiClear Premium TF-XL Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 159
Malfunction
Oil film in the drum filter module
8

Maintenance and cleaning

W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
Prior to reaching into the water, isolate (switch off and disconnect) all units/devices
used in the water.
Isolate the device (disconnect from the power supply) before carrying out any work
on it.
8.1

Cleaning the device

Do not use aggressive cleaning agents or chemical solutions as they could attack the hous-
ing or impair the function of the unit.
Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
After cleaning, thoroughly rinse all parts in clean water.
8.2

Regular tasks

The filter system is self-cleaning. Carry out the following work regularly to ensure the optimum
cleaning capacity of the filter system.
Regular checks
Check the display of the control system for any system messages. (→ System messagess)
Check the area in front of the separating plate and the inside of the filter drum for excessive
soiling (e. g. string algae). To do this, remove a screen element. (→ Removing the screen
element)
Removing accumulated dirt
Dirt that cannot be collected by the filter drum, sinks to the bottom and has to be removed.
Open the DN 75 dirt outlet for approx. 10 seconds once per month.
Remove accumulated dirt in front of the filter drum.
Remove string algae from the dirt channel.
Remove accumulated dirt from the level detection device.
Possible cause
Safety fuse has tripped due to a
blockage of the rinsing pump (exces-
sive current consumption)
Harmless food-grade oil may leak
from a new rinsing pump for a short
time when first used
- EN -
Remedy
Clean the rinsing pump (→ Cleaning
the rinsing pump)
• Replace the fuse
• Only use 5 × 20 mm, 16 A slow-blow
/ 250 V safety fuse.
No measure is necessary
79
Tabla de contenido
loading

Tabla de contenido