System message
20 cleaning cycles in suc-
Er33
cession
System message
Motor blocked
Er44
(The control system at-
tempted to start up the
motor three times - 5
times per attempt)
76
Functions that are still
Possible cause
available
Gravity fed systems only:
• Manual cleaning
• Time-dependent
Water level is beneath the level
cleaning
detection device
• Extended cleaning time
"Extra Cleaning"
Level detection device set too high
Water level in the system too low:
• Excessive flow rate (pump capaci-
ty too high)
• Water supply too low
• Water inlet blocked
Pump fed system only:
Level detection device set too low
Water level in the system too high:
• Outlet pipes soiled
• Outlet opening too small
• Excessive flow rate (pump capaci-
ty too high)
Functions that are still
Possible cause
available
None
Filter drum rotating sluggishly or
jammed
The lips of the drum seal were
squeezed when the drum was in-
stalled.
Remedy
• Increase the water level of the pond
• Use the OASE ProfiClear Guard refill system
• Set the level detection to a lower level (→ Setting the
level detection device)
− Setting the level detection to a lower level reduces
the movement of the Pond Pads in the filter system.
Set the level detection to a lower level (→ Setting the
level detection device)
− Setting the level detection to a lower level reduces
the movement of the Pond Pads in the filter system.
• Reduce flow rate (adjust pump capacity)
• Select a larger pipe diameter for the water supply if
necessary
• Clean water inlet
Adjust the level detection device (→ Setting the level
detection device)
• Clean outlet pipes
• Enlarge outlet opening
• Reduce flow rate (adjust pump capacity)
Remedy
• Clean edge of the drum/drum seal and grease edge
of the drum Only use original OASE grease (order
number 27872).
• Ensure that the rollers move smoothly
• Remove larger particles (e.g. snails, stones) from the
sprocket
• Disassemble the drum and ensure that the drum seal
is positioned correctly during re-assembly
Resetting the system
message
Press
key for 5 s
Resetting the system
message
Press
key for 5 s