N O T E
The unit will be destroyed if it is operated with a dimmer. It contains sensitive electrical
components.
Do not connect the unit to a dimmable power supply.
Do not transport the unit when it is filled.
N O T E
Never allow the rinsing pump to run dry. Possible consequences: The rinsing pump will
be destroyed.
Check the water level at regular intervals. Ensure that the rinsing pump is always un-
der water during operation.
Do not switch on the control system until the container is flooded with water.
T I P
During commissioning, Er88 is indicated in the display of the control system,
for as long as the final water level is not reached in the filter container,
when the pump status detection is not correctly set.
If the filter system operates correctly, the system message will reset automatically.
5.1

Pump-fed system

5.1.1

Order of starting up steps

How to proceed:
 A
1. Close the slide valve for the dirt outlet at the bottom of the container.
2. Check that the entire filter system (pipes and hoses) is complete.
3. Remove the container cover.
4. Manually turn the filter drum for one whole rotation to ensure unobstructed movement.
5. Fill the filter with water until the rinsing pump is submerged (dry run protection of the rinsing
pump).
6. Fit the container cover.
– The filter drum is stopped for safety reasons if the filter cover is lifted.
7. Switch on the control system and perform any necessary adjustments. (→ Operation)
8. Switch on the filter pump and UVC clarifier (if applicable).
– Ensure that the water is returned to the pond via the return pipe.
9. Check all pipes, hoses and their connections for leaks.
– Expansion seals may leak initially until they have fully expanded on contact with water.
10. Adjust the level detection device, if necessary. (→ Setting the level detection device)
66