5.4

Pump fed system without ProfiClear Premium Individual Module: Fitting the discharge set

Fit an outlet adapter with DN 110 pipe bend to each DN 150 outlet to ensure a suitable level of water in
the filter container. The height of the pipe bend outlet determines how high the water can rise in the filter
containers. Based on the physical principle of communicating pipes, the water balances out to the same
level in all containers. Ensure that the centre of the pipe bend outlet is 169 mm below the top edge of
the container. It is not necessary to fit pipe bends if the last filter module is a ProfiClear Premium
Individual Module.
OASE provides a suitable discharge set (Order No. 50949). It consists of two pipe bends/DN 110
adapters with holding plate.
4.
How to proceed:
H
1. If not already done: Fit the sealing ring into the wall of the container from the outside.
Ensure that the raised marking is at the top and aligned in relation to the hole pattern.
2. Fit the outlet adapter to the sealing ring.
Ensure that the raised marking is at the top and aligned in relation to the hole pattern.
3. Fasten the sealing ring and outlet adapter from the inside with oval head screws.
Tighten all screws diagonally using the cordless screwdriver to ensure that the sealing ring is
uniformly applied. Further tighten the screws using a Phillips screwdriver.
4. Fit the pipe bend set together in the specified order and fasten to the outlet adapter.
5. Guide the holding plate over the pipe bend and align the pipe elements if necessary.
6. Insert the screws with expansion seals through the holes from the inside. Screw the holding plate
from the outside to the container wall with cap nuts.
5.5

Returning the water to the pond

Once it has passed through all the cleaning stages, the clean water has to be returned to the pond.
There are various possibilities for this depending on the system used (please refer to the operating
manual for the Individual Module).