Cebora KINGSTAR 400TS Manual De Servicio página 65

Ocultar thumbs Ver también para KINGSTAR 400TS:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

CEBORA S.p.A.
inputs for external regulation of welding voltage (from UP/DOWN buttons);
inputs for external regulation of welding current (from external potentiometer);
inputs for external regulation of wire feed unit motor speed (from UP/DOWN
buttons);
inputs for recognition of torches or other connected accessories;
"arc on" signal output (NO contact, contact closed = arc on).
The "touch recognition" signal is used to identify devices connected to connector E,
control board (37) arranges welding system operation to ensure the connected
accessory is controllable by the signals.
The start signal of centralised attachment B is similar to that present in connector E
of connector board (219); because both circuits in motor control board (222) are
connected in parallel, only one of the two signals is enough to start the power source.
The pin-out of connector E is shown below:
3301045
65
17/09/2019