Italkero Echo XN-XC 18 Instrucciones De Instalación Y Mantenimiento página 34

Tabla de contenido
IA-200 Rev.0
ES – GB
ANOMALY
The burner shut down when is in function
The convector doesn't heat much
The tangential Fan doesn't start
Reduced hot air capacity
Fan doesn't commute the speed.
Burner doesen't commute the power.
20.10.2012
ES
Radiador mural a gas
Echo XC, XN y EN
Instrucciones de Instalación y Mantenimiento
EVENTUAL ANOMALY AND ITS REMEDIES
Unloaded & intake tubes assembled wrong
Gas pressure not correct or irregular
Selector knob on pilot position
Thermostat on low position
Gas pressure /injector not proper
Potency inadequate to the room
Supply mains disconnected
Air temperature is under the 50 ° C
Starting command in MIN position
Motor breakdown
Tangential fan failure
Obstruction over heat diffusion grill
Commutator is failure
Puede recibir soporte técnico en la sucursal/representación que a Ud. le corresponda.
La dirección la puede obtener en Internet o a través de la empresa Kromschroeder, S.A.
L'Hospitalet Barcelona.
CAUSE
Verify /replace:
Verify or regulate the gas pressure
Position on burner
Regulate the atmospheric thermostat On 7
Verify/check the gas and injector
Replace with a more power model
Verify
Verify
Switch over max
Replace
Replace
Verify / Release
Verify / Replace
-34-
GB
Wall gas Stove
Echo XC, XN y EN
Instructions of Installation and maintenance
REMEDY
-
Tube length
-
Tube and convector seal
If you have any technical questions please contact your local Branch office / agent.
The addresses are available on the internet or from Kromschroeder, S.A.
L'Hospitalet Barcelona.
IA-200 Rev.0
20.10.2012
Tabla de contenido
loading

Productos relacionados para Italkero Echo XN-XC 18

Este manual también es adecuado para:

Echo xn-xc 30Echo xn-xc 45TcTv-tvoCompact

Tabla de contenido