ANOMALY
The convector doesn't start
If the convector start (troubling functioning)
If the timer doesn't work
The atmospheric thermostat doesn't work
Spark absence
20.10.2012
ES
Radiador mural a gas
Echo XC, XN y EN
Instrucciones de Instalación y Mantenimiento
EVENTUAL ANOMALY AND ITS REMEDIES
Pilot doesn't light
Pilot doesn't remain lighted
Gas pressure not appropriate
Burned fuse
High room temperature greater than settled valeu
Air in the gas tube
Dirty injectors
Not proper Injectors for the gas used
gas Valve closed
Electrical switch off
Riders in the wrong position
Function selector in the wrong position
Supply switch disconnected
Thermostat knob doesn't regulate
Convector in wrong position
Superior /inferior grill clogged
Thermostat bulb out of his clip
Atmospheric thermostat breakdown
Electrode group defected:
- failures
- earth
- wrong connection
Starting knob not much pressed
or wrongly rotated
Piezoelectric ignitor failure
Puede recibir soporte técnico en la sucursal/representación que a Ud. le corresponda.
La dirección la puede obtener en Internet o a través de la empresa Kromschroeder, S.A.
L'Hospitalet Barcelona.
CAUSE
Verify/commute/replace:
Verify/commute/replace:
Regulate the proper pressure
Replace
Regular the atmospheric thermostat on 7
Take out the air through the pipes
Clean the injectors
Use the proper injectors
Verify or replace
Verify
Regular the riders
Position on watch
Reset and program the timer
Regular the thermostat knob
Change the Position
Relase
Set properly
Replace thermostat with gas valve group
Verify / Replace
Operate correctly on the knob
Replace the gas valve group
-33-
GB
Wall gas Stove
Echo XC, XN y EN
Instructions of Installation and maintenance
REMEDY
-
Irregular distance among injectors
-
Selector knob on worng position
-
Pilot injector dirty
-
thermocouple failures
-
dirty pilot
injectorfa
-
Fault gas valve
-
On 1 to decrease
-
On 7 to increase
If you have any technical questions please contact your local Branch office / agent.
The addresses are available on the internet or from Kromschroeder, S.A.
L'Hospitalet Barcelona.
IA-200 Rev.0
20.10.2012
Tabla de contenido
loading

Productos relacionados para Italkero Echo XN-XC 18

Este manual también es adecuado para:

Echo xn-xc 30Echo xn-xc 45TcTv-tvoCompact

Tabla de contenido