Technical Data; Set-Up And Commissioning Of The Saw; Unpacking (Fig. 1A And 1B); Setting Up The Saw - Proxxon DSH Manual De Instrucciones

Ocultar thumbs Ver también para DSH:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
The areas of application are multifaceted. Your DSH is particularly
suitable for mould construction, precision engineering model build-
ing and toy manufacture. For this reason, it is precisely the right tool
for designers, architects (model building) and carpenters.
The large-area, saw table 9 for mitre cuts can be titled up to 45°, is
manufactured from aluminium die casting for the highest precision
and stability, and is then ground for optimal glide properties.
The arrangement of the saw blade holders item 2 and 10 allow the
use of both saw blades with and without cross pin depending on the
area of application and the material of the tool. In the Proxxon
accessories range you will find the corresponding saw blades for the
respective task. We recommend that you use only Proxxon saw
blades!
The replacement saw blades are stored in the "saw blade garage"
12, on the side of the panelling of the top arm.
The DSH saws soft wood up to a thickness of 50 mm, plastic up to
30 mm and non-ferrous metals up to 10 mm.
The saw can also be used without problem for separating Plexiglas,
GRP, foam, rubber, leather and cork.
And so that the dust does not obscure the view of the cutting line
when working, there are automatically driven bellows with adjustable
air nozzle 8. An additional vacuum cleaner can also be connected. The
connecting piece 13 is positioned at 90° to save space.
This guarantees clean work.
Nur im Haus verwenden (hier Symbol einpflegen)
Gerät nicht im Hausmüll entsorgen (hier Symbol einpflegen)

5 Technical data

No. of strokes:
Stroke height:
Max. cutting depth
(in wood) at 45°
Cutting blade length:
Noise development::
Vibration
Measurements:
LxBxH
Table:
Saw frame radius
Motor:
Voltage:
Power consumption:
For use in dry environments only
Please do not dispose off the machine!
- 14 -
900 or 1400/min
19 mm
50 mm
25 mm
127 mm (with cross pin)
125-130 mm (without cross pin)
< 70 dB(A)
< 2.5 m/s
53 x 27 x 33 (in cm)
360 x 80 mm
400 mm
220/240 Volt, 50/60 Hz
145/205 W

6 Set-up and commissioning of the saw:

6.1 Unpacking (fig. 1a and 1b):

1. Unpack the device and remove it from the box. Ensure that the de-
vice is not lifted by the plastic panelling around the top arm 16.
2. For transport reasons, the saw table 9 is folded up at an angle of
about 45°. Turn the toggle 6 to tilt the table back into the horizon-
tal position (the precise setting is described below). Then close the
toggle 6 again.

6.2 Setting up the saw:

Note:
Safe and precise work is only possible with careful fixing!
1. Secure saw with two screws (Ø 6 mm, not included in scope of de-
livery) on a solid workbench. Use the drill holes intended for this
purpose (11, fig. 1) which are located at the front and back of the
saw base.

6.3 Adjust and set angle display (fig. 2):

1. Slightly loosen toggle 1 (fig. 2) and fold saw table 2 up to stop
screw 3.
2. Clamp saw blade 4! See the corresponding section 6.6.1 of these
instructions. Caution! Mains plug must not be connected.
3. Using an angle 5 on the saw table 2, check the right-hand angle
to the saw blade. The stop screw is preset. If this still has to be ad-
justed, you can adjust the setting yourself using an Allen key 7, as
shown in fig. 2, once the counter nut has been loosened. After cor-
rect setting, tighten the counter nut. Make sure that the stop screw
does not go out of position in this process.
4. Check the "zero" setting of the indicator 8, if necessary, correct af-
ter the fastening screw has been loosened. For precise working,
carry out sawing sample.
5. Saw a sample from a piece of wood and check the angle again, if
necessary adjust the saw table 2, indicator 8 or stop screw 3 as
shown in fig. 2.

6.4 Assembling the air nozzle (fig. 3):

1. Take parts for securing the air nozzles from the bag.
2. Screw the knurled screw 1 with clamping pieces 2 into the saw
frame.
3. Introduce the air nozzle pipe 3 into the hole on the opened clamp
pieces, adjust the pipe and slightly tighten the toggle 1.
4. Place the air hose 4 on pipe 3 and nipple 5.

6.5 Connecting the vacuum cleaner (fig. 4):

1. Place the vacuum hose 1 of the vacuum cleaner in the connecting
piece 2.
2. Switch on the vacuum cleaner before sawing so that the sawdust is
vacuumed and the suction device does not get blocked. For practi-
cal reasons, the PROXXON suction control device is recommended.
Tabla de contenido
loading

Tabla de contenido