Wiring the Hood with an
Integral Blower
7/ 8
6
1/ 8
4
"
(175 mm)
(105 mm)
Figure 6: Integral Blower Model VTN1030C
From Control Panel
Figure 7: Wiring the Hood with an Integral Blower
English 12
1/ 4
8
" (210 mm)
7/
8
8
(225 mm)
1/ 4
2
"
(57 mm)
3/ 4
6
"
(171 mm)
"
25"
(635 mm)
From Blower
Integral Blower models VTN630C and VTN1030C are
integrated into the hood at the time of installation (
models). For complete installation instructions see the
instructions supplied with the blower unit.
1. Remove junction box channel covering the wires (see
Figure 5 on page 11).
2. Remove circular knockouts (Figure 5 on page 11).
3. Connect the blower's Molex plug connector to the
"
connector present inside the hood, as shown in
Figure 7.
4. Install 1" (25.4 mm) conduit connector in junction box.
5. Run black, white, and green wires (#12 AWG) in 1"
(25.4 mm) conduit from the power supply to the
junction box.
6. Connect the power supply wires to the hood wires in
the following order: black to black, white to white, and
green wire to green ground screw on chassis. Use
spring type wire nuts supplied.
•
Lost or missing wire nuts should only be replaced
with spring type wire nuts rated for a minimum of
two (2) #18 gauge wires and maximum of four (4)
#14 gauge wires, UL & CSA rated to 600V and
302°F (150°C.)
7. Close the junction box cover.