Installation Preparation

The custom insert unit is designed for installation inside a
custom-built hood assembly. It is for ducting to the outside.
It cannot be used in conjunction with a recirculation unit.
Hood installation height above a cooktop, rangetop or
range can vary. To obtain the necessary installation height
above a cooktop, rangetop or range, consult the
appliance's installation manual.
NOTICE:
The hood could incur some damage from heat if a
THERMADOR PROFESSIONAL
rangetop is operated with multiple burners at high settings
under a hood that is installed at minimum clearances.
English 6
30" – 40"
(762 – 1,016 mm)
to Countertop
Figure 1: Typical Hood Installation
®
series range or
Hood Width
The hood width should be no less than the width of the
cooking surface. For proper performance, the housing must
cover the entire cooking surface.
Where space is not restricted, a wider hood can be used to
increase capture area.
Distance From Cooking Surface
The installation height ranges from a minimum height of 30"
(762 mm) to a maximum height of 40" (1,016 mm);
however, it is necessary to follow the cooking appliance
manufacturer's installation instructions for proper hood
height.
Unit Weight
When calculating the load for the housing support system,
be sure to consider the weight of the ventilation unit.
Model
VCIN36JP
60 lb (27.22 kg)
VCIN48JP
73 lb (33.11 kg)
VCIN54JP
82 lb (37.20 kg)
VCIB36JP
96 lb (43.54 kg)
VCIB48JP
111 lb (50.35 kg)
VCIB54JP
122 lb (55.34 kg)
IMPORTANT:
The supplied weights address only the ventilation unit
and blower. Installer must account for weight of any
materials of construction when calculating the total dead
weight load of installation, including but not limited to:
wall, tile, mortar, plaster, brick, finishes, partitions, and
other similarly incorporated architectural and structural
items. It is the responsibility of the owner and the
installer to determine if additional requirements and/or
standards apply to specific installations.
Weight
Table 3: Unit Weight with Blowers