Chapter 4
DANGER
8008684/YJC8/2015-03-30
2 5 8
8 008 684/RI57/2007-11-28
Mounting
Avoid incorrect alignment!
The devices must not be rotated through 180° on installation, and
must be mounted at the same height. After installation the display
elements must be on the same side and at the same height.
S
h
Fig. 4-3: Mounting orientation of C 2000 and M 2000
a = Correct
S = Sender
4.1
Mounting with swivel mount
The sender and receiver are each secured by two swivel mounts. The
screws a should be mounted towards the user side, so as to remain
accessible after mounting.
Fig. 4-4: Mounting of C 2000, M 2000 and M 2000-A/P with swivel mount
s = M8 fixing screw, not supplied
Multibeam Photoelectric Safety Switch M 2000
R
h
s = Incorrect
R = Receiver
© SICK AG • Safety Systems • Germany • All rights reserved
Operating Instructions
Safety Light Curtain C 2000
S
R
h = Height